Start-up work for new energy thermal management
In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, metal insulation hose temperature range -60 ~ 250 ° C; pressure ≤ 2.5 bar.
When the new energy thermal management configures the metal insulation hose and other pipelines carefully, when referring to its pressure and overpressure capability, caliber and temperature range, consider the lift pressure of the circulating pump inside the equipment. New energy thermal management should choose pipelines with good quality and sufficient volume such as seamless steel pipe as much as possible. The pipeline connection between new energy thermal management and controlled objects should be as short as possible to reduce bending. When the pressure of the new energy thermal management circulation pipeline is too large, the pipeline pressure is insufficient, the pipeline and the reactor will be cracked, and the high temperature and low temperature heat conduction medium may be sprayed, which may cause personnel injury, burns, frostbite and ignition. The possibility of flammable materials, etc.; the pollution caused by the loss of reactants, property damage, and even the possibility of poisoning. The connection of new energy thermal management pipelines should be sealed and firm, with measures such as anti-vibration, grounding, rust prevention and pressure keeping, which can effectively prevent cracks from leaking and corrosion of pipelines;
New energy thermal management The selection of thermal insulation materials should first consider the temperature range of new energy thermal management equipment. It is important to select flame retardant materials. The temperature range of thermal insulation materials should include the temperature range of this new energy thermal management equipment, and have a temperature greater than 30 °C. margin. When the user ignores this problem, there is a possibility of fire. The insulation material package should be sufficient, otherwise the equipment control will not achieve the expected effect.
Other components of the new energy thermal management pipeline include valve components, gaskets, pressure gauges, cooling towers, cooling water pumps, etc. In order to ensure the stable operation of new energy thermal management equipment, the temperature range, pressure range and use of these components should be fully considered. Environment, use media, power and other parameters.
The management of new energy thermal management equipment should be carefully read the corresponding instructions, and then detailed preparations should be made before the corresponding preparations.
Related recommendations
-
Meet at booth 6002 of Shanghai World Expo Hall【Testing Expo】9.14-9.16
316Exhibition name: Shanghai International Automobile Testing and Quality Control ExhibitionExhibition time: September 14-16, 2020Booth number: 6002Exhibition address: Shanghai World Expo Exhibition Hall, Hall 1,
View details -
Daily maintenance instructions for heating and cooling circulators
2094After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to? To ensure the normal operation of the heating and cooling circulator after it is star...
View details -
Introduction of refrigerators for metal workpieces such as deep-frozen bearings
1813LNEYA's continuous-freezing work piece cryogenic box has a fast cooling rate, and the low temperature can reach -150℃. It can be used for cold assembly of bearings and mechanical parts. The cryogenic treatment can improve the mechanical properties...
View details -
Maintenance method of minus 17 ° C ultra-low temperature refrigerator
2313After the long-term use of the ultra-low temperature refrigerator of minus 17 °C, it is necessary to carry out certain maintenance work. If the user does not know how to carry out the maintenance work, you can contact the manufacturer to obtain th...
View details