Description of the characteristics of the LNEYA walk-in test chamber
LNEYA walk-in test chamber Characteristics:
Wide temperature control range can meet the user’s various needs.
Unique balanced temperature control method, a stable and balanced heating capacity can be used for high precision and high stable temperature control.
The temperature displayed by touch screen, easy to read, precise and convenient.
The temperature error can be adjusted to meet your more accurate test conditions.
Automatically selecting and running the cooling circuit with the setting of temperature, with simple operation.
The door is equipped with a large observation window, which can observe the test status of the sample.
With high temperature starting function, the chamber can be turned on when the temperature in rises to 100 degrees. It is convenient for continuous round-trip test between high temperature and low temperature.
With self-diagnosis function, overload protection , high pressure switch, overload relay, thermal protection device, etc.
With multi-wing fan used to circulate and avoid any dead Angle, so that the temperature can be distributed evenly in the test area.
The air circuit is designed with the wind return wind, the wind pressure and wind speed are in accordance with the test standard, and can make the opening instant temperature regain fast.
Heating, cooling, and completely independent system can improve efficiency, reduce test cost, increase life span and reduce failure rate.
The water tank is placed on the side of the unit with water shortage and automatic protection.
The humidifying system is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline to improve the safety.
The system of waterway system is opened by door to facilitate maintenance and repair.
In the refrigeration system, the condensation adopts air – cooling mode or water – cooling mode.
LNEYA’s walk-in test chamber has 15 volumes that can be customized.
Related recommendations
-
Dual-channel chillers for semiconductor manufacturing industry
2090Dual-channel chillers are used in a variety of processes in the semiconductor manufacturing industry. The main purpose is to provide precise temperature control to ensure that the equipment in the semiconductor manufacturing process operat...
View details -
There are usually three ways to control the temperature of laboratory reactors
18751. Manual control: Manually operate the knob on the front of the reactor controller.2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.3. Controlled by thermostat: Silicone oil...
View details -
Equipment attention points of laboratory high and low temperature cycle equipment manufacturers
2143In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...
View details -
Precautions for use of LNEYA’s Recirculating chiller
2178LNEYA's low temperature recirculating chillercan be used with supporting instruments (such as rotary evaporators,fermentation tanks, chemical reactors, freeze-drying equipment,biopharmaceutical reactors, etc.), with large cooling capacity and f...
View details
LNEYA Thermo Refrigeration Co.,Ltd