LNEYA cooling and heating thermostat bath instructions
Circulating thermostatic water bath is water circulation and cooling function based on the increase in the water bath, can improve the precision of temperature control and temperature stability, can be widely used for drying, distillation, concentration, dipping in chemical reagents, impregnation of pharmaceutical and biological products, can also be used for constant heating water and other temperature test, is a biological, genetic, viral, aquaculture, environmental protection, medicine, health, biochemical laboratory, analysis room, education and scientific research necessary tools.
As we all know, there are very few impurities in the water, so does distilled water after adding to the tank.
For heating and cooling thermostatic baths, the general temperature is set at 20 ℃, specially adapted to the growth and reproduction of microorganisms. After a long time, these microorganisms will clog the waterway filter, lead to backwater, then the pump will have large noise.
Sometimes these microorganisms are attached to the surface of the heat exchanger, reducing the effectiveness of heat transfer, and making the refrigeration quantity smaller.
Therefore, the routine maintenance must be strictly executed in accordance with the requirements of the manual. Clean the inner grooves regularly and keep dry during long-term shut-down.
When Heating and cooling Thermostatic Bath seems to be a leak, sometimes the ground for a few drops, check if there is a leakage on the waterway? Generally, it will not leak during abnormal usage. When the ambient temperature is relatively high in the air together with large humidity, the moisture on the pump, water pipe joints, external water pipes of the waterway in the water circulation are easily condensed out as dew, then accumulated and dropped to the ground, so do not worry whether there is somewhere leak. If you care about it, turning on the air-conditioning to reduce room temperature or dehumidifying can prevent the dew.
Related recommendations
-
Maintenance steps of slope heating and cooling cooling heating thermostat
1953The slope temperature rise and fall cooling heating thermostat is the center to clean dust, garbage, etc. To clean and change inspection, inspection can find problems, find the potential defects of the slope temperature rise and fall high and low...
View details -
What are the reasons for the power consumption of large-size refrigeration units?
2009During the operation of large-size refrigeration units, the cooling capacity and working conditions are the main issues of power consumption, but in order to avoid some unnecessary power consumption, we need to understand clearly. When the scale o...
View details -
What type of chiller is needed for low-temperature etching?
2005The low-temperature etching process usually requires extremely high precision temperature control and strong cooling ability to maintain stable operation of the etching equipment at extremely low temperatures, in order to achieve finer etching eff...
View details -
Main differences between indoor chillers and outdoor chillers
2295Although indoor chillers and outdoor chillers are both devices used to provide cold water to meet specific cooling needs, they have significant differences in design, installation location, working environment, and heat dissipation methods. Instal...