Heat transfer oil secondary circulation system use instructions
The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation.
LNEYA heat transfer oil secondary circulation system uses branded fully enclosed compressors with advanced performance and reliable quality. The relays, protectors, capacitors and other devices used in the equipment are all original high-quality equipment, ensuring the reliable performance and service life of the heat transfer oil secondary circulation system, integrating cooling, heating and circulation, and the power distribution of the heat transfer oil secondary circulation system is reasonable. Save space.
The heat transfer oil secondary circulation system should be filled with liquid medium in the front tank. Generally, the liquid level is 30mm-50mm below the work surface to prevent the heater from being burnt. The power supply is 220VAC/50Hz, and the equipment must have good grounding. The circulation pump is automatically turned on when the equipment starts to operate, and the refrigeration compressor will make corresponding start or stop commands according to the temperature of the equipment unless there is a special need.
LNEYA heat transfer oil secondary circulation system adopts the automatic control function of circulating pump, that is, when the equipment is running, the circulation pump runs automatically. When the equipment is running, because of the function of the self-contained circulation pump, the liquid surface will show a flowing pattern if running. When there is no obvious flow state at the liquid tank interface, it means that there may be a helium state, and it should be exhausted in time. The device has its own cooling function. The cooling function can automatically issue a running or stop command according to the temperature of the device. It can also prohibit the compressor from running through the system parameters. When the device prohibits the compressor from running, the compressor needs to be set again to return to normal. Cooling operation.
The equipment should be placed in a ventilated and dry place, and the back and sides should be separated from the obstacle by more than 300mm. After use, turn off the power switch and unplug the power cord. If it is not used for a long time, the liquid in the tank should be drained and scrubbed clean.
When using the heat transfer oil secondary circulation system, it is necessary to pay more attention to the above problems, so that the use can achieve more efficient operation efficiency.
Related recommendations
-
Importance of refrigerants in new energy vehicle battery test systems
2735If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of...
View details -
Common faults of plate heat exchangers in new energy vehicle inspection
2764The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
View details -
Semiconductor refrigeration temperature control system accessories
2185In the evaporator, since the liquid evaporates in the evaporator of the semiconductor refrigeration temperature control system, the process from liquid to gas, due to the change of the load, some of the refrigerant may not be completely evaporated...
View details -
Hydraulic system cooling and heating temperature control system
1681The application of cooling and heating temperature control system in hydraulic system is very critical, especially in occasions where precise temperature control is required. This system can ensure that the hydraulic oil is kept within the require...
View details
LNEYA Thermo Refrigeration Co.,Ltd