A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
We are a top chiller manufacturer. Welcome to buy our products.
관련 권장 사항
-
Hot and cold dynamic constant temperature control equipment cryopump installation points
1215The performance of each component in the cold and heat source dynamic constant temperature control equipment is different. We must make full use of each accessory to make the equipment run better. The cryopump is one of the main accessories, and i...
세부 정보 보기 -
공랭식 정밀 냉각기 보호에 대한 설명
1112공랭식 정밀 냉각기가 필요한 곳은 작동 정확도에 대한 요구가 높다는 것을 나타냅니다. 따라서 보호 설정이 잘 작동해야 합니다. 그렇다면 공냉식 정밀 냉각기에 대해 어떤 종류의 보호를 수행해야합니까?
세부 정보 보기 -
Is the temperature control equipment for semiconductor component testing a chiller?
933Semiconductor component testing temperature control equipment is used in the simulation test of the temperature performance of semiconductors, chips and other components, and conducts temperature tests in different temperature ranges within the ra...
세부 정보 보기 -
Purchasing Strategy of Ultra-low Temperature Freezer
982The performance of refrigeration system determines the overall performance. If refrigeration technology is good, excellent refrigeration effect can be achieved quickly. It takes only 4-5 hours on average from room temperature to minus 8 degrees Ce...
세부 정보 보기