ISG/TM 모터 테스트 냉각 시스템 고전압 고장 및 처리 조치
ISG/TM 모터 테스트 냉각 시스템은 업계에서 공랭식과 수랭식의 두 가지 유형으로 나뉩니다. 작동 원리는 먼저 기계의 물 탱크에 일정량의 물을 주입한 다음 ISG/TM 모터 테스트 냉각 시스템을 통과시켜 물을 냉각하는 것입니다. 그런 다음 저온 냉각수는 워터 펌프를 통해 냉각될 장비로 보내집니다. 냉각 된 물은 열을 제거한 다음 온도가 상승하여 물 탱크로 돌아와 냉각을 달성합니다....

ISG/TM 모터 테스트 냉각 시스템 고전압 고장 및 처리 조치
(1). The cooling water temperature is too high and the condensation effect is poor. ISG/TM motor test cooling system has high water temperature and poor heat dissipation, which will inevitably lead to high condensing pressure. This phenomenon often occurs in high-temperature seasons. The reason for the high water temperature may be: cooling tower failure, such as the fan is not turned on or even reversed, the water distributor does not turn, it is manifested as the cooling water temperature is very high and rising rapidly; the outside temperature is high, the water path is short, and the amount of water that can be circulated In this case, the cooling water temperature is generally maintained at a relatively high level, which can be solved by increasing the storage tank.
(2) The cooling water flow rate is insufficient, and the rated water flow rate is not reached. The main performance is that the pressure difference between the inlet and outlet water of the unit becomes smaller (compared with the pressure difference at the beginning of the system’s operation), and the temperature difference becomes larger. The reason for the insufficient water flow is the lack of water in the system or the presence of air. The solution is to install an exhaust valve at the height of the pipeline to exhaust; the pipeline filter is blocked or the selection is too fine, and the water permeability is limited. You should choose a suitable filter and Clean the filter regularly; the water pump is small and does not match the system.
(3), the condenser is fouled or blocked. Condensate water generally uses tap water, which is easy to scale, and because the cooling tower is open, it is directly exposed to the air. Dust and foreign matter can easily enter the cooling water system, causing the condenser to be dirty and blocked, the heat exchange area is small, and the efficiency is low. Affect water flow. The performance is that the pressure difference and temperature difference between the inlet and outlet water of the unit become larger, and the upper and lower temperatures of the condenser are very high when the condenser is touched by hand. The unit should be backwashed regularly, and chemical cleaning and descaling should be carried out if necessary.
(4), the refrigerant is overcharged. This situation generally occurs after maintenance, and it is manifested as high suction and exhaust pressure and balance pressure, and high compressor operating current. It should be vented according to the suction and discharge pressure, balance pressure and operating current under rated conditions until normal.
(5), the refrigerant is mixed with non-condensable gases such as air and nitrogen. This situation generally occurs after maintenance, and the vacuum is not at the bottom. It can only be drained, re-evacuated, and recharged with refrigerant.
(6) False alarms caused by electrical faults. Because the high-voltage protection relay is damp, poorly contacted or damaged, the unit electronic board is damp or damaged, and the communication failure causes a false alarm. This kind of false fault, often the HP fault indicator on the electronic board is not bright or slightly bright, the high-voltage protection relay manual reset is invalid, the computer displays “HPRESET”, or disappears automatically, the running current of the compressor is normal, and the suction and discharge pressures are also normal.
관련 권장 사항
-
산업용 냉동 장비의 4방향 밸브를 교체하는 방법은 무엇입니까?
916The four-way valve of industrial refrigeration equipment needs to be replaced in time after a long period of use, so how to replace it? When replacing industrial refrigeration equipment, you need to first remove the connecting pipe connecting the ...
세부 정보 보기 -
산업용 재순환 냉각기의 구조적 특성
926화학 반응에는 반응 온도에 대한 엄격한 요구 사항이 있습니다. 화학 반응을 원활하게 수행하려면 온도를 적절한 온도로 높여야 합니다. 반응 후, 다시 온도는 ...
세부 정보 보기 -
Wuxi Guanya Low Temperature Test Chamber With 12 Years Brand ranked the top ten in China!
730Throughout the low temperature test chamber industry, there are no less than thousands of manufacturers. Almost every family is confident about their products, but from the feedback complaints and after-sales situation of users, Wuxi Guanya Thermo...
세부 정보 보기 -
공정 엔지니어링에서 동적 온도 제어 시스템의 온도 제어
948화학 산업, 특히 공정 엔지니어링에서는 많은 공정이 온도에 묶여 있거나 특정 온도 제어 애플리케이션에 의해 지원될 수 있으므로 효율성이 높아집니다. 후자의 예로는 연속 온도 제어가 있습니다.
세부 정보 보기