KRYCH 시리즈 배터리 팩 테스트 챔버
애플리케이션
The power battery temperature cycle chamber is a high and low temperature test device for power battery samples. It is currently mainly used in the new energy battery industry. It can directly complete high and low temperature charging and discharging, or high and low temperature storage, for battery cells, modules, and PACKs in the test box. In the event of battery failure, explosion-proof pressure relief and fire protection devices are added.
제품 특징
제품 매개변수
GD series & KRYCH series -40℃~100℃
모델 | GD-9000-2-B1-KRYCH-4A15W | GD-9000-2-B1-KRYCH-475W | GD-9000-2-B1-KRYCH-4A10W | GD-1000-B1-KRYCH-475 | |||||
온도 범위 | -40℃~100℃ 부동액 |
-40℃~100℃ 테스트 챔버 |
-40℃~100℃ 부동액 |
-40℃~100℃ 테스트 챔버 |
-40℃~100℃ 부동액 |
-40℃~100℃ 테스트 챔버 |
-40℃~100℃ 부동액 |
-40℃~100℃ 테스트 챔버 |
|
부동액 흐름 제어 | 1L/min~40L/min | 1L/min~25L/min | 1L/min~25L/min | 1L/min~10L/min | |||||
±0.2L/min | ±0.2L/min | ±0.2L/min | ±0.2L/min | ||||||
부동액 압력 | Measure and display the inlet and outlet pressure, as well as the pressure displayed on the touch screen | ||||||||
Chamber(W*H*D) | Upper cavity cm | 220*322*120 | 220*322*120 | 220*322*120 | Single cavity:100*100*100 | ||||
Lower cavitycm | 220*322*110 | 220*322*110 | 220*322*110 | ||||||
난방 전력 | 15kW | 14kW | 7.5kW | 14kW | 10kW | 14kW | 7.5kW | 6kW | |
냉각 용량 부동액 |
135℃ | 15kW | 7.5kW | 10KW | 7.5kW | ||||
20°℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
0℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
-20℃ | 10kW | 4.5kW | 6KW | 4.5kW | |||||
-35℃ | 4kW | 1.8kW | 2.5KW | 1.8kW | |||||
Chamber | Heating rate | 25~+100℃≥±2℃/Min (No load, average throughout the entire process) (Customizable at 5~25℃) | |||||||
냉각 속도 | 25~-40℃≥1℃/Min(No load, average throughout the entire process) (Customizable at 5~25℃) | ||||||||
Antifreeze temp control accuracy | ±0.1℃ | ||||||||
Temperature uniformity | ≤±1℃(unloaded) | ||||||||
Circulating air volume | 5000m³/h | 2500m³/h | |||||||
제어 모드 | Segmented Fuzzy PID Algorithm Control | ||||||||
통신 프로토콜 | CAN/TCP/RS485 | ||||||||
온도 피드백 | Internal temperature of equipment enclosure, condensation temperature of refrigeration system, suction temperature of compressor, cooling water temperature (for water-cooled equipment) |
||||||||
High temp cooling module | Can cool down from a high temperature of 100 ℃ | ||||||||
순환 펌프 | 자기 구동 펌프 | ||||||||
압축기 | Brand variable frequency compressor | ||||||||
증발기 | Plate/fin heat exchanger | ||||||||
냉장 액세서리 | Emerson/Danfoss brand dry filters, oil separators, etc | ||||||||
스로틀 방법 | 전자식 팽창 밸브 | ||||||||
냉매 | R125/R404A | ||||||||
안전 보호 | Phase sequence failure protector, freezer overload protection; High pressure switch, overload relay, thermal protection device and other safety protection functions. |
||||||||
water-cooled condenser | Shell and tube heat exchanger | ||||||||
조작 패널 | 10 inch color touch screen | 7인치 컬러 터치 스크린 | |||||||
Antifreeze interface | ZG3/4 | ZG3/8 | |||||||
Cooling water 20 ℃ | 25m³/H | 20m³/H | 20m³/H | 7m³/H | |||||
치수 cm | 240*560*285 | 240*560*285 | 240*560*285 | 120*205*205 | |||||
Bearing | 1500kg | 1500kg | 1500kg | 120kg | |||||
무게 | 4600kg | 4200kg | 4200kg | 600kg | |||||
전원 공급 장치 | 380V 50HZ | ||||||||
Insulation material | Glass fiber cotton&polyurethane | ||||||||
Inner box material | SUS304 stainless steel brushed plate | ||||||||
External materia | Cold rolled steel plate+spray coating | ||||||||
Execution standards | GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068 |
Why choose lneya as your temperature control supplier?
18+
Years of experience
30000+
Satisfied Customers
25000
m² Production Area
80+
Patented Technologies
Visit LNEYA factory