Application of Industrial Air-Cooled Chiller in Chemical Industry
Industrial air-cooled chillers are applicable to glass reactors, metal reactors and bioreactors for temperature control. In the field of chemistry and pharmacy, air-cooled chillers usually carry out necessary temperature control together with the chemical reaction of the material itself. Through the temperature change of circulating medium in sheath or coil, the temperature control of materials and the target process temperature of materials can be realized.
For the temperature control of stroke water cooler in pharmaceutical industry, the requirements for selecting temperature control equipment are relatively high. Compared with the common temperature range of – 60 ℃ – 100 ℃, a wider working temperature range is required. At the same time, different chemical reactions require different temperature curves, and the high-temperature and low-temperature integrated units need to work at any different temperature point within this temperature range.
The high and low temperature integrated device for temperature control of air-cooled chiller adopts electric heating, which can quickly increase the temperature of circulating medium. It adopts energy-saving design to realize the regulation of refrigeration capacity, accurately control the temperature of materials, realize the endothermic or rapid response to exothermic of materials, and meet the drug production needs of most industrial occasions.
The characteristics of explosion-proof air-cooled chiller are as follows:
(1) The cascade compression refrigeration cycle of the refrigeration unit can reach a lower temperature. Electric heating can quickly increase the temperature of the circulating medium.
(2) The adjustment of refrigerating capacity change is realized. The refrigerant flow is mainly controlled by PID, and the material temperature is accurately controlled. The traditional method is to use electric heating to offset the cooling of the compressor, which wastes energy.
(3) The combined control of heating and cooling realizes the rapid response to the heat absorbed or released by the material.
(4) The control of material temperature is mainly realized by refrigerant flow control. The refrigerant proportional control valve adopts the valve body of electronic expansion valve. Higher temperature control accuracy can be achieved.
The temperature control of air-cooled chiller consists of refrigeration cycle system, heating cycle system and automatic control system. For areas where the equipment has explosion-proof requirements, the positive pressure explosion-proof cabinet can be customized, which not only meets the explosion-proof requirements, but also reduces the number of explosion-proof parts and reduces the production cost of the whole machine.
관련 권장 사항
-
리액터용 장비는 어떻게 선택하나요?
901원자로의 장비 선택은 다음 사항에 따라 측정해야 합니다: 1. 가열 방법: 일반적으로 전기 가열은 3톤 이상이어야 하며, 외부 하프 파이프의 경우 3톤 미만에서 3톤 이상이어야 합니다.
세부 정보 보기 -
대마초 추출 산업의 구세주 대마초 오일 냉각기 | CBD 냉각기
1139대마, 대마초, CBD/THC 산업이 급성장하고 있습니다. CBD 및 THC 오일의 품질을 유지하려면 효율적이고 효과적인 장비가 필요합니다. 오일은 적절하게 보존하지 않으면 산패되거나 분해될 수 있습니다. 냉장고나 알코올을 다시 장착하는 것은 ...
세부 정보 보기 -
산업용 재순환 냉각기의 구조적 특성
895화학 반응에는 반응 온도에 대한 엄격한 요구 사항이 있습니다. 화학 반응을 원활하게 수행하려면 온도를 적절한 온도로 높여야 합니다. 반응 후, 다시 온도는 ...
세부 정보 보기 -
What are the influencing factors of the industrial refrigerator with minus 200 degrees?
1071In order to better use the industrial refrigerator with a temperature of minus 200 degrees, you need to understand some influencing factors and how to avoid it. The oil temperature will have an important effect on the viscosity of the industrial r...
세부 정보 보기