How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
Nowadays, many pharmaceutical and chemical industries use LNEYA’s constant temperature control system. How to judge its operation status during operation?
There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic control system, only the normal and regular sound of the inhalation valve. The condenser cooling water should be sufficient, the water pressure should be above 0.12MPA, and the water temperature should not be too high. There should be no foot heating and frosting on the cylinder wall, and the surface temperature difference should not exceed 15-20 degrees. For refrigerated or low-temperature systems, frosting on the suction pipe can generally reach the suction port; for high-temperature conditions, the suction pipe should not be condensed Frost, condensation is normal.
Chemical and pharmaceutical constant temperature control system Crankcase oil temperature small constant temperature control system does not exceed 70 degrees and not less than 10 degrees. The lubricating oil may have foam, and the exhaust temperature should not be too high. Too high and close to the flash point of domestic refrigeration oil will be detrimental to the equipment. The condensing pressure is not easy to be too high, and the construction capacity of the condensing pressure cold storage is affected by the water source, condensing method and refrigerant. The oil level of the crankcase shall not be lower than 1/2 of the horizontal centerline of the sight glass.
Chemical and pharmaceutical thermostatic control system. The hand-touched horizontal accumulator and oil separator should be cool in the upper part and lower part, and the liquid or oil level at the junction of cold and hot. The safety valve or bypass valve should be cool at the low pressure end, otherwise the high and low pressure series gas. During operation, the evaporating pressure and the suction pressure should be similar, and the exhaust pressure and condensing pressure should be similar to the accumulator pressure.
There should be a temperature difference between the cooling water in and out of the chemical and pharmaceutical constant temperature control system. If there is no or very slight temperature difference, it means that the heat exchanger is dirty and needs to be cleaned. The system should be sealed, and no refrigerant or lubricating oil should be leaked. The shaft seal of the fluorine small constant temperature control system should not drip oil. The temperature of the shaft seal and bearing of the constant temperature control system for chemical and pharmaceutical industries does not exceed 70 degrees. The valve body of the expansion valve is evenly frosted or condensed, but there should be no thick frosting at the inlet. When the fluid passes through the expansion valve, only a dull, small sound can be heard. The pointers of the pressure gauges in the system should be relatively stable and the temperature indication should be correct.
The above conditions related to the chemical and pharmaceutical thermostatic control system can be used to judge the operation status. It is recommended that the operator observe more to determine the faulty sound in time and solve it effectively.
관련 권장 사항
-
재결정화 온도와 영향을 미치는 요인은 무엇인가요?
876재결정화는 용매에 용해되거나 녹은 후 용액 또는 용융물에서 결정을 재결정화하는 과정입니다. 재결정화는 불순물을 정화하거나 혼합된 염을 서로 분리할 수 있습니다. 그중에는 ...
세부 정보 보기 -
12마력 냉동고 열전달 오일 선택 지침
1210When choosing a 12hp freezer, users need to pay attention to the choice of heat transfer oil. For LNEYA, suitable heat transfer oil is very important. What should you pay attention to when choosing heat transfer oil? The 12hp freezer adopts a full...
세부 정보 보기 -
2018 CIPM China | You have an invitation to the exhibition from LNEYA
1270The 56th (Fall 2018) National Pharmaceutical Machinery and China International Pharmaceutical Machinery Expo will be held from November 5th to November 7th, 2018 at Wuhan International Expo Center. As one of the professional communication platfor...
세부 정보 보기 -
산업용 재순환 냉각기의 구조적 특성
926화학 반응에는 반응 온도에 대한 엄격한 요구 사항이 있습니다. 화학 반응을 원활하게 수행하려면 온도를 적절한 온도로 높여야 합니다. 반응 후, 다시 온도는 ...