Method for controlling shutdown of water cooled chiller of single reaction kettle
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
관련 권장 사항
-
공냉식 냉각기의 특징 및 장점
11691. 공냉식 칠러의 구성공냉식 칠러는 압축기의 종류에 따라 공냉식 볼텍스 칠러와 공냉식 스크류 칠러로 나눌 수 있습니다. 공냉식 볼텍스 칠러는 주로 볼텍스 압축기, 증발 ...
세부 정보 보기 -
LNEYA의 재순환 냉각기 사용 시 주의사항
1195LNEYA's low temperature recirculating chillercan be used with supporting instruments (such as rotary evaporators,fermentation tanks, chemical reactors, freeze-drying equipment,biopharmaceutical reactors, etc.), with large cooling capacity and f...
세부 정보 보기 -
Cooling and heating temperature control equipment for liquid distribution system
925The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution s...
세부 정보 보기 -
Ultra Low Temp Freezer DW of LNEYA
1721Ultra Low Temp Freezer DW Description: Ultra-low temperature freezer mainly used for scientific research, special materials of low-temperature test and preservation; freezing of red blood cells, white blood cells, skin, bacteria, semen, biological...
세부 정보 보기