Characteristics and Advantages of Air Cooled Chillers
1. Configuration of air-cooled chiller
Air cooled chillers can be divided into air-cooled vortex chillers and air-cooled screw chillers according to the type of compressor. The air-cooled vortex chiller is mainly composed of vortex compressor, evaporator, condenser, refrigeration element, circulating water pump, stainless steel water tank and original imported fan electric control system. The air-cooled screw chiller is composed of screw compressor, evaporator, condenser, refrigeration components, imported fan and electric control system. All the above parts are guaranteed to be 100% new and original. Welcome new and old customers to our factory for on-site inspection.
2. Protective device of air-cooled chiller
Long service time or improper operation of air-cooled chiller will cause unit failure. In order to ensure the safe and stable operation of chiller, the equipment itself is equipped with multiple safety protection devices, such as reverse phase protection device, compressor overload protection device, high and low pressure protection device, automatic alarm device, low temperature anti icing protection device, etc. Even if the chiller fails, the protection device can be started at the first time to avoid secondary injury to the chiller.
3. Temperature control of air-cooled chiller
Both air-cooled box chillers and air-cooled stacked rod chillers can meet the refrigeration temperature required by various industries, up to 350 ℃ and down to – 150 ℃. Moreover, the temperature adjustment can be set on the control panel of the chiller according to the demand. The specific setting method can be in accordance with the operation manual of the chiller.
4. Energy saving and environmental protection of air-cooled chiller
Chillers belong to mechanical equipment, and the primary problem considered by users is power consumption. One feature of air-cooled chiller is that after reaching the refrigeration temperature required by users, the compressor stops running to save electric energy. When the temperature is higher than the temperature set by the user, the compressor will restart to save power consumption for the user to a certain extent. In addition, for chillers with multiple compressors, each compressor has an independent refrigeration system. Users can decide the number of compressors to be started according to production needs, which is more flexible and convenient to use.
Related recommendations
-
Several elements of the operation of -20 degree industrial cryogenic chiller
2524-20 degree industrial cryogenic chiller is a refrigeration equipment that provides low temperature chilled water. It is often used in production enterprises, such as chemical companies, pharmaceutical companies and other production processes, to p...
View details -
Industry and introduction of low temperature chiller
1862In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, ...
View details -
Relationship Between Poor Refrigeration Performance And Refrigerant In Low Temperature Industrial
1854The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are rela...
View details -
Development prospect of temp measurement and temperature control device for microfluidic chip system
2621With the continuous development of China's science and technology, there has been great progress in the field of integrated circuits and chips. The temperature measurement and temperature control devices in the LNEYA microfluidic chip system have ...
View details
LNEYA Thermo Refrigeration Co.,Ltd