For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure.
Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipments are open, whether all the water tanks are filled with water, whether the fans are reversed, and whether the circulating water pump is running in the correct direction. Open the super deep crying treatment main power supply (the standard power supply is 3-phase five-wire system 380V 50HZ), specifically the water-cooled ultra-deep cold treatment front nameplate. Wuxi Guanya LNEYA reminds everyone that the power supply for ultra-deep cooling must be stable to avoid burning the unit or compressor and pump motor.
First open the ultra-deep cooling treatment cooling switch, then turn on the chilled water pump switch. Since the compressor has a delayed start function, the compressor will automatically run after the delay. At this time, pay close attention to the front control panel to observe the temperature change, as appropriate according to the cooling demand. Perform temperature adjustment. Water-cooled ultra-cry cryogenic treatment During normal operation, the unit operation data should be recorded periodically to facilitate the identification of problems based on data as soon as the unit fails. The ultra-cryogenic treatment itself is provided with multiple protection devices. Once there is a fault, it will start to protect and automatically stop. After the fault is removed, press the reset to operate normally.
When the super-cryogenic treatment is not used, the unit, water pump, insulated water tank and water in the pipeline should be drained, and the equipment should be covered and protected to avoid dust and other debris. Regarding the maintenance of ultra-deep cold treatment, this cannot be ignored. It is necessary to clean the condenser and evaporator after running for half a year. It is recommended to carry out maintenance of the whole machine after one year of operation, and keep it clean and clean regularly.
The instruction manual of the ultra-cryogenic treatment equipment and regular inspection and maintenance are all parts that the user needs to know in order to make the equipment run more efficiently.

관련 권장 사항
-
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
1506When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
세부 정보 보기 -
대형 산업용 냉장고 증발기 작동 지침
1233In the operation process of Wuxi Guanya LNEYA large industrial refrigerator, due to the large number of parts and complex, we need to understand the operation of the components in large industrial refrigerators. The evaporator is one of the main c...
세부 정보 보기 -
일반적인 연료전지 환경 테스트 장치 검사 방법
1234연료전지 환경 테스트 장치의 냉각 과정에서 내부에 물방울이 떨어질 수 있습니다. 이는 연료 전지 환경 테스트 장치에서 사용하는 정상적인 현상이 아니라 부적절한 설치로 인해 발생합니다. 연료 종료 후 ...
세부 정보 보기 -
글리콜 냉각기 설치 시 주의사항은 무엇인가요?
1069In the summer, the use of glycol chillersis relatively frequent. Therefore, when installing glycol chillers, they needto be installed on a smooth and tidy floor. Why choose a smooth ground wheninstalling? Users who have known the glycol chiller...
세부 정보 보기