Common fuel cell environmental test device inspection method
During the cooling process of the fuel cell environmental test device, there is a chance of dripping inside. This is not a normal phenomenon used by the fuel cell environmental test device, but is caused by improper installation. After the fuel cell environmental test device is installed, test the machine (refrigeration) immediately. If there is no water leakage after running for a certain period of time, there will be no leakage problem. Of course, the installer can also be required to carry out the water leakage test, and the water is introduced into the internal machine, and the water naturally flows out of the outdoor water through the water receiving tray and the down pipe.
The fuel cell environmental test device will emit a certain amount of noise, but if the noise is too large, it may be caused by improper installation. During the installation, the inner wall panel is not nailed, and the inner machine is not fixedly dead, which may easily lead to excessive noise. In this case, the installer can easily find and correct the problem by testing the machine.
The installation position of the fuel cell environmental test device is also very particular. It is not where the user likes to install it. Otherwise, it will lead to maintenance troubles and poor cooling effect. The households should avoid heavy oil smoke, wind and sand, direct sunlight and heat dissipation. Where there is a poor or high-temperature heat source, it is also necessary to avoid hidden dangers such as flammable gas leaking easily, strong corrosive gas, artificial strong electricity or direct magnetic field action.
If the joint of the fuel cell environmental test device is not tightened, cracked, etc., fluorine leakage may occur. If fluorine is leaking, the user should always replenish it. The normal use of the fuel cell environmental test device generally does not require the addition of refrigerant for several years. The refrigerant leak check should be performed before the test machine. The leak detection is mainly for the four interfaces of the internal and external connecting pipes of the household fuel cell environmental test device and the valve port of the shut-off valve. Soap water (you can also use detergent) leak detection is one of the commonly used methods in the field. After opening the valve for 10 to 15 seconds (the cabinet is 20 to 30 seconds), the valve is closed, and the parts in the system are quickly filled more than A gaseous refrigerant with an air pressure of 0.8 MPa. Apply soapy water to the suspicious point of the leak. If there is a bubble, it will leak. If it is observed for 3 minutes, no bubbles will appear.
The regular installer will check the user’s power supply before installing the fuel cell environmental test device. If the requirements are not met, the user is advised to change it. The power cord is not installed in accordance with the specifications, and it is prone to leakage and fire, which endangers the user’s personal safety. The installer is required to test the power supply with the associated power detection tool.
Since the fuel cell environmental test device has a certain requirement in the fuel cell test, the above faults are avoided as much as possible.
Related recommendations
-
How to Choose Chiller and Injection Moulding Machine?
2119A. First way:The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force i...
View details -
Vehicle high temperature and high humidity test vehicle anti-aging performance
2097On test benches in the automotive industry, accurate temperature simulation is critical. From the time of the test, the air temperature in the test chamber has always been maintained at 45 ℃, which is equivalent to the hottest area of the Flaming...
View details -
Battery test water cooler common knowledge description
2409Battery test Water-cooled air intake If there is no superheat, there may be a return air with liquid, and even cause a wet stroke liquid shock to damage the compressor. In order to avoid this phenomenon, a certain degree of suction superheat is re...
View details -
Installation and maintenance of industrial water chiller
1910As a industrial temperature control device,industrial water chiller is often in 24-hour operation. Therefore, it is veryimportant to choose a industrial chiller with good performance. Wuxi GuanyaRefrigeration Technology Co., Ltd. specializes in...
View details
LNEYA Thermo Refrigeration Co.,Ltd