What are the precautions for the installation of glycol chiller
In the summer, the use of glycol chillers
is relatively frequent. Therefore, when installing glycol chillers, they need
to be installed on a smooth and tidy floor. Why choose a smooth ground when
installing? Users who have known the glycol chiller should know that if the
glycol chiller is tilted during installation, it may cause the refrigerant or
cooling water or chilled water to operate abnormally, and the refrigerant may
flow backward or the resistance may increase, which is not conducive to The
normal operation of the refrigeration system.
The glycol chiller can run the compressor
on a stable surface to make the compressor run more efficiently. Because the
normal operation of each component of the compressor takes into account the
gravity problem, the smooth ground can avoid the resistance of the liquid
medium in the flow or the acceleration of gravity, and the glycol chiller can
be operated more efficiently.
Of course, the noise problem is also
plaguing many users of glycol chillers. In fact, the flat ground can
effectively reduce the vibration and noise during operation, because the flat
ground can reduce the vibration during operation, which is beneficial to its
ethylene glycol. Silence effect to enhance its service life.
If the glycol chiller is operated on a
non-flat floor, due to the effect of gravity, the probability of loosening and
peeling off under the vibration generated by the
operation of the glycol chiller is greater.The user can install it according to
the requirements.
LNEYA low temperature circulator has a wide
refrigeration temperature range, and the controllable temperature is – 150 ° C to – 5 ° C.
Secondary subcooling is adopted, which has fast cooling speed, safety and
reliability. It is used for rapid liquid cooling. It is widely used in
petrochemical, medical, pharmaceutical, biochemical, freeze-drying,
pharmaceutical and other high-tech industries. A single compressor can achieve
– 152 ℃ temperature control, and the ultra-low temperature refrigeration
technology is at the international advanced level. To save water resources,
ethylene glycol water mixture can be used for circulating refrigeration, and
the design of circulating pipeline shall be strict to prevent circulating water
pollution and prolong the service time of circulating water; Overlapping
subcooling refrigeration technology.
Related recommendations
-
Laboratory crystallization temperature control cooling and heating system
1788In the laboratory crystallization process, temperature controlled cooling and heating system is a crucial component used to precisely control the temperature of the crystallization solution, in order to achieve high purity, specific morpho...
View details -
Battery test chiller operation evaporating temperature description
2306In the current new energy vehicle battery test equipment, the use of more batteries to test the chiller evaporation temperature has a certain impact on the equipment, then what is the specific impact? When the battery test chiller heat load increa...
View details -
General high and low temperature integrated machine valve repair detailed description
2731The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the ...
View details -
Multi-stage refrigeration small temperature control compressor description
2135The function of the compressor in the multi-stage refrigeration small temperature control station system is to draw the refrigerant vapor of the evaporator and increase its temperature and pressure, which is discharged into the condenser. In the c...
View details
LNEYA Thermo Refrigeration Co.,Ltd