DC 충전 파일 냉각 시스템을 설치할 때 주의해야 할 사항은 무엇인가요?
1.Understand the characteristics of the DC charging pile cooling system
Before installing a DC charging pile cooling system, you need to understand the characteristics of the equipment. This includes things like the device’s size, weight, operating temperature range, and power requirements. Ensure that the equipment has sufficient space and power required for its operation at the installation site, and ensure that the operating temperature range of the equipment meets actual requirements.
2.Dealing with common problems of DC charging pile cooling system
During the installation and use of the DC charging pile cooling system, you may encounter some common problems. Here are solutions to common problems:
- Insufficient cooling/heating effect: This may be caused by scaling inside the equipment, blocked pipes, or insufficient refrigerant. Maintenance and maintenance should be carried out regularly, including cleaning internal scale, replacing filters, adding refrigerant and other measures.
- Equipment abnormality: If the equipment has abnormal sound, vibration or odor, it should be shut down immediately for inspection. It may be caused by damaged internal parts of the equipment, broken pipes, or other reasons. The manufacturer or maintenance personnel should be contacted in time for maintenance.
- Electrical failure: If the equipment cannot start normally or other electrical failures occur, you should check whether the power connection is normal and whether the wires are damaged or loose. If you cannot solve it yourself, you should seek help from an electrician.
- Waterway system problems: If the equipment has problems such as water leakage, insufficient water volume, or abnormal water temperature, you should check whether the waterway system is well sealed and whether the accessories are damaged. If you cannot solve it by yourself, you should contact the manufacturer or maintenance personnel for repair.
As a device that can provide both high and low temperature environments, the correct installation and use of the DC charging pile cooling system is crucial to giving full play to its performance. This article will discuss the points to note during the installation of the DC charging pile cooling system.
7 * 24 무료 상담 및 종합 솔루션 제공


이메일: sales@cnzlj.com
WhatsApp: 086 13912479193
관련 권장 사항
-
직접 접촉식 액체 냉각과 냉각판 액체 냉각 기술의 차이점
1290냉각판 액체 냉각 기술은 가열 부품의 열을 냉각판을 통해 순환 파이프 라인에 둘러싸인 냉각 액체에 간접적으로 전달하고 열을 ...
세부 정보 보기 -
-
How to use the 4kW new energy charging pile cooling system?
8624kW liquid cooling chiller for new energy charging pile
세부 정보 보기 -
Basic structure manual of industrial chiller
1277Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
세부 정보 보기 -
다중 원자로를 위한 냉장 및 가열 온도 제어 시스템
9951. 여러 제조업체의 여러 원자로의 냉동 및 가열 온도 제어 시스템의 품질과 구성에는 약간의 차이가 있습니다. 일부 장비는 작동 중에 약간의 소음이 발생하며 소음은 ...
세부 정보 보기 -
저온 냉장 수조에서 흔히 발생하는 디버깅 문제는 무엇인가요?
1437저온 냉각조가 디버깅 중일 때 국부 냉각 효과가 좋지 않으면 시스템이 이물질에 의해 막히거나 시스템 설계가 불합리하여 정상적으로 조정할 수 없습니다. 이때 LNEYA는 이물질을 제거하고 ...
세부 정보 보기 -
Application area of high temperature refrigeration and cooling control system