Chiller for 200L distillation kettle
The chiller for 200L distillation kettle needs to meet two main functions at the same time:
One is to condense methanol vapor, and the other is to cool the material during the reaction process.
When choosing a suitable chiller, there are several key factors to consider:
- 냉장 용량
- Condensing methanol: The boiling point of methanol is about 64.7°C (at standard atmospheric pressure). Therefore, the chiller needs to be able to provide cooling capacity below this temperature, usually around 5-10°C.
- Material cooling: The refrigeration capacity of the chiller is determined based on the specific reaction temperature and the required cooling rate. For example, if the material needs to be quickly cooled from high temperature to room temperature or lower, the chiller needs to have sufficient cooling power.
- Flow rate and pressure
- Condenser: The condenser requires a certain cooling water flow rate to ensure effective condensation. The flow rate is usually between a few liters per minute and tens of liters per minute, depending on the design and size of the condenser.
- Reactor: The cooling of the material in the reactor also requires sufficient flow rate and pressure to ensure a uniform cooling effect. Generally, the flow rate should be in the range of 10-30 L/min, depending on the capacity of the reactor and the heat load of the material.
- 온도 제어
- Accuracy: To ensure effective condensation of methanol and stable cooling of materials, the refrigerator should have high-precision temperature control, usually with a control accuracy of ±1°C or less.
- PID controller: The use of a PID controller can achieve fast and stable temperature adjustment to ensure that the system operates within the set temperature range.
- Safety protection measures
- Overtemperature protection: Automatically cut off the power supply when the temperature exceeds the set value.
- Overpressure protection: Prevent the system pressure from being too high.
- Leak detection: Detect whether the system has leaks.
- Emergency stop button: Quickly stop the system in an emergency.
- Operation interface
- Touch screen or digital display: Intuitively display the current temperature, set temperature and other parameters.
- User-friendly operation interface: Easy to set and monitor temperature, support programming and data logging functions.
Recommended Configuration
- Chiller type
- Water-cooled chiller: Suitable for large capacity and high efficiency requirements. Heat is removed by circulating cooling water, suitable for industrial production environments.
- Air-cooled chiller: Suitable for occasions with limited space or insufficient water supply. The fan blows air through the heat sink to take away the heat.
- 냉장 용량
- Select the appropriate refrigeration capacity according to the specific needs of the 200L distillation kettle. Assuming that you need to cool the material from high temperature to room temperature or lower in a short time, you can choose a chiller with a refrigeration capacity in the range of 5-10 kW.
- 순환 펌프
- Flow rate: 10-30 L/min
- Head: Select the appropriate head according to the resistance of the system, usually around 10-20 meters of water column.
- Temperature control system
- PID controller: achieve high-precision temperature control.
- Temperature sensor: installed at key positions of the condenser and reactor to monitor the temperature in real time.
- Safety protection device
- Overtemperature protection: automatically cut off the power supply when the temperature exceeds the set value.
- Overpressure protection: prevent the system pressure from being too high.
- Leak detection: detect whether the system has leaks.
- Emergency stop button: quickly stop the system operation in an emergency.
In summary, the chiller supporting the 200L distillation kettle needs to meet the needs of condensing methanol and cooling the material at the same time. When choosing a suitable chiller, you should consider the cooling capacity, flow and pressure, temperature control accuracy and safety protection measures. It is recommended to use a water-cooled chiller equipped with a PID controller and multiple safety protection devices to ensure efficient, safe and reliable operation of the system. It is recommended to consult a professional equipment supplier or engineer before purchasing to ensure that you choose the chiller that best suits your needs.
CHILLERS fordistillation kettle
LT -45℃~30℃
저온 냉각 서큘레이터 빠른 액체 냉각을 위해 1. 순환 냉장을 위해 물과 혼합 된 에틸렌 글리콜을 사용하여 자원 절약 2. 순환 파이프 라인 설계, 연장 ...
LT 10℃~30℃
Saving water resources & circulating cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong the use time of circulating …
LT -25℃~30℃
Rapid refrigeration using imported brand semi-enclosed piston compressor, semi-enclosed piston two-stage compressor, semi-enclosed screw compressor 1. Can use ethylene glycol mixed …
로딩 중...
이미 마지막 에피소드에 도달했습니다!
LN -60°C~ -10°C
适用範围 产品特性 产品参数 产品参数 行业应用 应用 航空天材料|试验装置控温解決方案 航空天领域,材料的性能直接關係到飞机的安全、可靠性和和...
LJ -45°C~ -10°C
빠른 냉각 및 낮은 냉각 온도 -5~-150°C 수냉식 LNEYA는 단일 유체 극저온 냉각기 생산을 전문으로 합니다. 냉동 온도 범위는 -150°C에서 -5°C까지이며, 이는 ...
LD -80°C~ -30°C
1. 온도 범위는 -5 ℃ ~ -150 ℃이며 다른 온도 2를 충족시킬 수 있습니다. 유명 브랜드 반 폐쇄 형 피스톤 압축기, 반 폐쇄 형 바이폴라 피스톤 압축기, 반 밀폐형 스크류 압축기, 주요 브랜드는 BOCK입니다. 비처, 경찰 ...
SLJ -110℃~-150℃
1. 온도 범위는 -5 ℃ ~ -150 ℃이며 다른 온도 2를 충족시킬 수 있습니다. 유명 브랜드 반 폐쇄 형 피스톤 압축기, 반 폐쇄 형 바이폴라 피스톤 압축기, 반 밀폐형 스크류 압축기, 주요 브랜드는 BOCK입니다. 비처, 경찰 ...
CDLJ -110°C~ -50°C
5kW 냉각기; 10kW 냉각기; 30kW 냉각기; 60kW 냉각기; 120kW 냉각기 저온 반응, 냉장 속도, 안전 및 신뢰성 분야의 화학, 제약, 생화학 및 기타 산업에서 널리 사용됩니다 ...
로딩 중...