반도체 제조 공정 중 멀티채널 냉각기가 필요한 공정은 무엇입니까? 왜 필요한가요?
In the semiconductor manufacturing process, multi-channel chillers are mainly used in key process links that require high-precision temperature control and large-scale heat management.
Here are some typical usage scenarios and reasons:
Chemical Vapor Deposition (CVD): In the CVD process, a multi-channel chiller is used to cool the reaction chamber walls, heat exchangers, and gas preheating exchangers to maintain stable reaction chamber temperature, ensuring precise control of film thickness, uniformity, and chemical reactions.
Etching and etching: Both dry etching and wet etching require precise temperature control. The multi-channel chiller ensures the temperature of the etching equipment and chemical bath, which affects the etching rate, selection ratio, and graphic accuracy.
Ion implantation: The ion source and target chamber need to be cooled by a chiller to control temperature, prevent overheating from affecting ion energy dispersion, and ensure the accuracy of injection depth and dosage.
Heat treatment: such as oxidation, diffusion, annealing, nitriding, multi-channel chiller controls furnace temperature to ensure uniform temperature, affecting diffusion rate, activation, and impurity distribution.
Testing equipment: such as probe testing and aging testing benches, multi-channel chillers control the testing environment temperature to ensure equipment stability and reproducibility of test results, especially for high or low temperature testing.
Why do need a multi-channel chiller?
Temperature control accuracy: Multi channel design can more accurately control the temperature of each area, reduce temperature fluctuations, and ensure process consistency.
High heat load management: Semiconductor manufacturing generates a large amount of heat energy, and multi-channel can effectively handle a large amount of heat load to ensure equipment operation safety and efficiency.
Flexibility: Multiple channels can be independently adjusted to meet specific temperature requirements of different processes or equipment sections, increasing process flexibility.
Reliability: Redundant hot backup, single channel failure does not affect overall operation, improves system stability, and reduces downtime.
In summary, the application of multi-channel chillers in semiconductor manufacturing is based on high requirements for temperature control accuracy, thermal energy management, production efficiency, and process stability, ensuring the performance and yield of semiconductor devices.
관련 권장 사항
-
최신 웨이퍼 제조의 반도체 냉각기 애플리케이션
713냉각기가 웨이퍼 팹에서 어떻게 정밀한 온도 제어를 보장하는지 알아보세요. 리소그래피, 에칭, CMP 등의 주요 애플리케이션에 대해 알아보세요.
세부 정보 보기 -
열교환 냉각기 ETCU
3119온도 범위 : + 5 ℃ ~ 90 ℃ ± 0.3 ℃ 냉각 용량 : 5kw ~ 30kw 탱크 용량 : 6L ~ 15L 전력 : 06KW ~ 1.6KW 40 ℃ 이내의 가열 방식은 압축기 고온 가스 가열 완전 밀폐 설계를 채택하고 기계는 작동합니다 ...
세부 정보 보기 -
반도체 제조 기업에 가열 서큘레이터 장비가 필요한 이유는 무엇일까요?
1127온도 제어 정확도: 반도체 제조 공정은 온도 제어에 대한 요구 사항이 매우 엄격합니다. 가열 순환기는 정밀한 온도 제어를 제공하여 온도가 일정하게 유지되도록 보장할 수 있습니다.
세부 정보 보기 -
FLT -45℃~40℃
1927Model FLT-402 FLT-402W FLT-403 FLT-403W FLT-404 FLT-404W FLT-406 FLT-406W FLT-408 FLT-408W FLT-410 FLT-410W FLT-415 FLT-415W Temp Control -45℃~40℃ Temp control accuracy ±0.1℃ Flow Control 10~25L/min 5bar max 15~45L/m...
세부 정보 보기