Water chiller for high and low temperature testing of aviation fuel
High and low temperature cooling of aviation fuel usually requires the use of water-cooled chillers rather than air-cooled chillers. This is because water-cooled chillers have higher energy efficiency and better temperature control accuracy, and are more suitable for the cooling needs of aviation fuel.
Application of water chillers in high and low temperature testing of aviation fuel:
Low temperature requirements:
- Fuel freezing point test: used to test the freezing point of aviation fuel at low temperatures to ensure that the fuel will not freeze under cold conditions.
- Low temperature performance test: evaluate the performance parameters such as fluidity and viscosity of aviation fuel under low temperature conditions to ensure that the fuel can be transported and burned normally at low temperatures. In cold areas, the fuel may need to be cooled between -40°C and -50°C.
High temperature requirements:
- Thermal stability test: evaluate the thermal stability of aviation fuel under high temperature conditions to ensure that the fuel will not decompose or produce harmful substances under high temperature conditions.
- Volatility test: test the volatility of the fuel at high temperatures to ensure that the fuel will not volatilize excessively under high temperature conditions. In high temperature areas, the fuel may need to be cooled between 30°C and 40°C.
Temperature Cycle Test:
•Thermal Cycle Performance Test: Simulates the cyclic changes of aviation fuel under different temperature conditions to evaluate the performance stability of the fuel under temperature change conditions. It is usually necessary to control the temperature within the range of ±1°C to ±0.5°C to ensure the stability and safety of the fuel during transportation and storage.
Temperature Variation Range:
•Aviation fuel may experience large temperature changes in different seasons and regions, so the cooling system needs to be able to adapt to a wide temperature variation range. The water chiller needs to be able to operate over a wide temperature range, usually covering a range from extremely low temperatures (such as -60°C) to higher temperatures (such as above 40°C). The ability to quickly switch between high and low temperatures to simulate the rapid temperature changes of aviation fuel under different temperature conditions is very important for evaluating the thermal cycle performance of the fuel.
In summary, water-cooled chillers are more suitable for the high and low temperature cooling needs of aviation fuel due to their high energy efficiency, precise temperature control and stability. When selecting a chiller, it is also necessary to consider factors such as specific application scenarios, cooling requirements, available space, and ease of maintenance.
LN -60°C~ -10°C
适用範围 产品特性 产品参数 产品参数 行业应用 应用 航空天材料|试验装置控温解決方案 航空天领域,材料的性能直接關係到飞机的安全、可靠性和和...
LJ -45°C~ -10°C
빠른 냉각 및 낮은 냉각 온도 -5~-150°C 수냉식 LNEYA는 단일 유체 극저온 냉각기 생산을 전문으로 합니다. 냉동 온도 범위는 -150°C에서 -5°C까지이며, 이는 ...
LD -80°C~ -30°C
1. 온도 범위는 -5 ℃ ~ -150 ℃이며 다른 온도 2를 충족시킬 수 있습니다. 유명 브랜드 반 폐쇄 형 피스톤 압축기, 반 폐쇄 형 바이폴라 피스톤 압축기, 반 밀폐형 스크류 압축기, 주요 브랜드는 BOCK입니다. 비처, 경찰 ...
SLJ -110℃~-150℃
1. 온도 범위는 -5 ℃ ~ -150 ℃이며 다른 온도 2를 충족시킬 수 있습니다. 유명 브랜드 반 폐쇄 형 피스톤 압축기, 반 폐쇄 형 바이폴라 피스톤 압축기, 반 밀폐형 스크류 압축기, 주요 브랜드는 BOCK입니다. 비처, 경찰 ...
CDLJ -110°C~ -50°C
5kW 냉각기; 10kW 냉각기; 30kW 냉각기; 60kW 냉각기; 120kW 냉각기 저온 반응, 냉장 속도, 안전 및 신뢰성 분야의 화학, 제약, 생화학 및 기타 산업에서 널리 사용됩니다 ...
로딩 중...
이미 마지막 에피소드에 도달했습니다!
관련 권장 사항
-
열 편향 온도 계측기용 냉각기
984온도 범위: 냉각수의 온도는 일반적으로 6 ℃에서 18 ℃ 사이가 필요합니다.온도 차이 요구 사항: 냉각수의 온도 차이는 위트로 제어해야합니다 ...
세부 정보 보기 -
LTZ 인버터 M 시리즈
1684응용 분야 대상 온도 제어 대상에 적용하기에 적합한 저온 저장 탱크와 순환 펌프가 이미 있으며 매체가 LTZ M 시리즈 냉동 온도 제어 장치를 통해 LTZ M 시리즈 냉동 온도 제어 장치로 이송됩니다.
세부 정보 보기 -
추출 및 분리에서 고온 및 저온 순환 장비를 사용하는 방법은 무엇입니까?
906과학과 기술의 지속적인 발전으로 고온 및 저온 사이클 산업용 온도 제어 장비는 많은 분야, 특히 추출 및 분리 분야에서 중요한 역할을 합니다. 이 기사는 ...
세부 정보 보기 -
LT 10℃~30℃
2725Saving water resources & circulating cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong the use time of circulating ...
세부 정보 보기