
main differences between indoor chillers and outdoor chillers
Although indoor chillers and outdoor chillers are both devices used to provide cold water to meet specific cooling needs, they have significant differences in design, installation location, working environment, and heat dissipation methods.
The following are the main differences between indoor chillers and outdoor chillers:
Installation location:
Indoor chiller: As the name suggests, installed inside buildings such as computer rooms, equipment rooms, laboratories, data centers, etc., located in the same indoor environment as the cooled equipment or system.
Outdoor chiller: installed outside buildings, such as roofs, terraces, dedicated equipment platforms, or floors, separated from the cooled equipment, usually in an open or semi open outdoor environment.
Working environment:
Indoor chiller: The working environment is relatively stable, less affected by external climate changes, and factors such as temperature, humidity, and dust are relatively controllable. But it is necessary to consider the ventilation, noise control, and coordinated layout with other equipment in the indoor space.
Outdoor chiller: Directly exposed to outdoor climate conditions, the working environment changes greatly, and needs to cope with various weather conditions (such as high temperature, low temperature, wind and rain, sand and dust, etc.), and may face greater corrosion risks. Design should consider measures such as rain protection, sun protection, dust prevention, frost resistance, and anti heat island effect.
Heat dissipation method:
Indoor chiller: Heat dissipation is usually achieved through air-cooled or water-cooled condensers. The air-cooled indoor chiller uses a built-in fan to directly discharge the heat generated by the condenser into the indoor air, which is then discharged through the indoor ventilation system. The water-cooled indoor chiller is connected to a cooling tower or cooling water system to transfer heat to the outside through the circulation of cooling water.
Outdoor chiller: It often uses air-cooled condensers to use outdoor air for natural or forced convection heat dissipation. Outdoor chillers are usually equipped with large air flow fans and large-area heat dissipation fins to enhance heat dissipation efficiency. In cold regions, antifreeze devices such as electric heaters or hot gas bypass valves may also be required.
Noise control:
Indoor chiller: Due to its installation indoors, there are high requirements for noise control, and noise reduction measures are usually designed, such as soundproof covers, silencers, low-noise fans, etc., to reduce the impact on the working environment.
Outdoor chiller: Although installed outdoors and relatively less sensitive to noise, it still needs to comply with certain environmental standards and community regulations. Some high-end outdoor chillers adopt appropriate noise reduction designs, but overall, their noise control requirements are slightly lower compared to indoor chillers.
Maintenance convenience:
Indoor chiller: Due to its relatively concentrated location, it is easy for daily inspection and maintenance. But it may be necessary to consider the entry and exit channels of indoor space, equipment relocation, and coordination with other facilities.
Outdoor chiller: During maintenance, it may be necessary to consider safe climbing, harsh weather conditions, and compatibility with the building’s exterior. However, due to its distance from the work area, the impact of maintenance operations on normal operations is relatively small.
Installation costs and limitations:
Indoor chillers: Factors such as indoor space occupation, ventilation facility renovation, and increased air conditioning load may need to be considered, especially in places with limited space or special environmental requirements (such as clean rooms), where installation costs and complexity may be high.
Outdoor chiller: It is necessary to consider outdoor installation conditions such as building structural load-bearing, waterproofing, lightning protection, drainage, power supply, insulation, as well as possible regulatory limitations such as urban planning, environmental protection, and noise control.
In summary, there are significant differences between indoor and outdoor chillers in terms of installation location, working environment, heat dissipation method, noise control, maintenance convenience, installation cost and limitations. The selection of which type should be based on factors such as actual application environment, building conditions, cooling requirements, cost budget, and local regulations.
LTZ 인버터 M 시리즈
응용 분야 대상 온도 제어 대상에 적용하기에 적합한 저온 저장 탱크와 순환 펌프가 이미 있으며 매체가 LTZ M 시리즈 냉동 온도 제어 장치를 통해 LTZ M 시리즈 냉동 온도 제어 장치로 이송됩니다.
LN -60°C~ -10°C
适用範围 产品特性 产品参数 产品参数 行业应用 应用 航空天材料|试验装置控温解決方案 航空天领域,材料的性能直接關係到飞机的安全、可靠性和和...
LT -80℃~-20℃
24 시간 연속 작동을 보장 할 수 있습니다. 물 혼합물과 혼합 된 에틸렌 글리콜의 순환 냉동 1. 순환 냉장을 위해 물과 혼합 된 에틸렌 글리콜을 사용하여 자원을 절약 할 수 있습니다.
- 자세히 보기
LTZ 가변 주파수 M 시리즈
이미 저온 저장 탱크와 순환 펌프가 있는 대상 온도 제어 대상에 적합합니다. 매질은 폐쇄 루프 냉동 장치 인 순환 펌프를 통해 LTZ M 시리즈 냉동 장치로 이송됩니다.
LTG 스크류 냉각기 장치
화학, 제약, 기계 및 기타 분야의 다양한 생산 공정 냉원에 적합하며 -110 ℃ ~ 30 ℃ 냉동 매체를 제공 할 수있어 얼음 저장, 저온 공기 공급 및 외기 공급으로 사용할 수 있습니다.
ZLTZ 효율적인 열교환기 시리즈
The ZLTZ temperature control unit is combined with a microchannelreactor to form a high heat release temperature control application.Under the same f…
LT-800 미니 냉각기
이미지는 연결 효과 만 보여줍니다. 저온에서 화학적, 생물학적 및 물리적 실험이 필요한 저온 조건에서 널리 사용되며, 그것은 ...
LJ -45°C~ -10°C
빠른 냉각 및 낮은 냉각 온도 -5~-150°C 수냉식 LNEYA는 단일 유체 극저온 냉각기 생산을 전문으로 합니다. 냉동 온도 범위는 -150°C에서 -5°C까지이며, 이는 ...
LD -80°C~ -30°C
1. 온도 범위는 -5 ℃ ~ -150 ℃이며 다른 온도 2를 충족시킬 수 있습니다. 유명 브랜드 반 폐쇄 형 피스톤 압축기, 반 폐쇄 형 바이폴라 피스톤 압축기, 반 밀폐형 스크류 압축기, 주요 브랜드는 BOCK입니다. 비처, 경찰 ...
LT -45℃~30℃
저온 냉각 서큘레이터 빠른 액체 냉각을 위해 1. 순환 냉장을 위해 물과 혼합 된 에틸렌 글리콜을 사용하여 자원 절약 2. 순환 파이프 라인 설계, 연장 ...
LT -60℃~-20℃
Circulating refrigeration of ethylene glycol mixed with water mixture After the medium enters the extraction tank, it must be closed,the sandwich is heated, and the refrigerant is turned on to reducethe heat source of the…
로딩 중...
이미 마지막 에피소드에 도달했습니다!
관련 권장 사항
-
Explosion-proof high and low temperature one machine manufacturer instructions installation point
674After the explosion-proof high and low temperature integrated machine is delivered from the factory, it must be installed after reaching the destination. What should you pay attention to when installing? The explosion-proof high and low temperatur...
세부 정보 보기 -
Points to pay attention to when choosing a reactor temperature cycle control machine
511The temperature circulation control machine of the reaction kettle has always been an indispensable equipment for pharmaceutical and chemical enterprises. As a refrigeration and heating experimental equipment, if the purchased reactor temperature ...
세부 정보 보기 -
Simulation control of temperature change in the cooling and heating temperature control system of th
437Industrial cooling and heating temperature control system is a temperature control equipment used in the cooling and heating process of reaction kettle in the pharmaceutical and chemical industry. What are the characteristics of lneya's equipment?...
세부 정보 보기 -
How to reduce the condensing pressure of the heating circulator unit?
558During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor w...
세부 정보 보기