How to reduce the condensing pressure of the heating circulator unit?
During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor will continue to increase, resulting in a gradual decrease in the cooling capacity, which indirectly makes the equipment cycle worse. It is necessary to appropriately reduce the condensing pressure.
1. Then, when the condensing pressure of the heating circulator unit is too low, the power supply of the throttle valve is insufficient, and the high-pressure liquid pipe is continuously affected by the heating factor, which will reduce the capacity of the throttle valve.
2. The pressure of the condenser can be controlled by adjusting the heat exchange capacity of the condenser. When the heat exchange of the condenser is large, the gas discharged from the compressor is fully condensed, and the condensing pressure gradually decreases; if the heat exchange performance of the condenser is weakened, the condensing pressure continues to rise.
3. The condenser can adjust the cooling water flow to control the condensation pressure. Install a regulating valve on the condenser cooling water outlet pipe. There are two modes for the water volume control valve: one is a temperature type water volume control valve that uses the temperature at the outlet of the cooling water of the condenser to indirectly send a letter. It has a temperature sensor that is inserted into the condensate outlet. When the water temperature rises, the valve opens large; when the water temperature decreases, the valve closes small. The other is a pressure-type water volume regulating valve that directly sends a signal from the condensing pressure, and the pressure signal is drawn from the condenser. When the condensing pressure gradually increases, the valve opens large; when the condensing pressure decreases, the valve closes small, thereby changing the cooling water flow of the condenser.
4. The self-contained cooling tower circulation system can be used. In order to prevent the condensation pressure from being too low, it can be adjusted by the water bypass valve, which makes part of the water from the condenser sent to the cooling tower for cooling, and the other part is returned to the bypass. water outlet.
For the LNEYA heating circulator unit, if multiple pumps are used in parallel, the number of running pumps can be changed to adjust the flow rate according to the constant change of the condensing pressure.
Related recommendations
-
Wuxi Guanya: Focus on R&D of refrigeration heating equipment to help develop new energy
2599On October 17, 2018, the three-day API was held in Nanjing International Expo Center. The exhibition was crowded with people. Wuxi Guanya was a frequent visitor to the API. Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. (herei...
View details -
Semiconductor Test Temperature Cycle Chiller Development
2327The semiconductor chip IC industry is currently a relatively new industry in China. As the requirements of the chip industry become higher and higher, the test difficulty is also constantly strengthened. To this end, LNEYA introduced the semicondu...
View details -
The Mid-Autumn Festival Appreciation Dinner ended successfully
2579The autumn wind is refreshing, and the Mid-Autumn Moon is rounder. At the juncture of time, the annual Mid-Autumn Festival is about to usher in. In this beautiful festival, Wuxi Guanya is full of love and the Mid-Autumn Festival Appreciation Dinn...
View details -
About the components of the reactor chiller refrigeration heating circulator
2447The reactor chiller refrigeration and heating circulator is used to control the heater and cooler, adjust the temperature, and maintain the stable temperature of the material. Through the circulating medium, the temperature of the material can be ...
View details
LNEYA Thermo Refrigeration Co.,Ltd












