Discussion on maintenance of high and low temperature integrated cycle machine
LNEYA high and low temperature integrated cycle machine is a refrigeration heating equipment produced by the use of refrigeration heating dynamic temperature control technology. The temperature range is from -120 °C to 350 °C. It has superior performance, high precision and intelligent temperature control. It needs regular time when used. Do a good job of maintenance.
The high and low temperature integrated cycle machine exchanges heat or direct contact heat exchange mode to exchange heat of the medium and cool it through the cooling tower to recycle water to save water resources. In general, the circulating water is neutral and weakly alkaline, and the pH is controlled between 7 and 9.5; in the case of circulating cooling water in direct contact with the medium, it is acidic or alkaline (pH greater than 10.0), generally less.
Always check whether the cooling water pipe is connected safely and securely. Is the flow, temperature and pressure of the cooling water suitable? It is recommended to check the water level of the water tank every month. Once the water level drops, it should be replenished in time and only distilled water can be added. In order to prevent the growth of microorganisms or free organic impurities in the water, so as not to impede the flow of water and affect the cooling effect, it is recommended to add a bactericide in the water, and the distilled water in the water tank is replaced at least once a year. The blades of the air-cooled filter and the cooling fan of the compressor should be cleaned every 6 months. After the cleaning is completed, 12 drops of oil should be added to the fan bearing. In order to reduce the impact of scale on flow and cooling capacity, it is recommended to clean the pipeline every 5 years (if it is cooled with tap water every 2 years).
The high and low temperature integrated cycle machine is very convenient to install and move, but it requires a higher working environment because it is cooled by hot air circulation. Therefore, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. In addition, if you want to put the equipment in a dust-free workshop with humidity requirements, then I advise you to modify the water-cooled.
Related recommendations
-
Methods for Chiller Manufacturers to Ensure Product Quality
1894Before producing the industrial chiller, the chiller manufacturer will consider the applicable industry, refrigeration capacity, structure, etc., and consider the actual use environment during design and assembly to optimize some functions. In ord...
View details -
New energy automobile motor comprehensive test system
2443When the LNEYA new energy vehicle motor integrated test system is running, the control panel settings are required. At the time of setting, if the user does not know how to use it, you can check the manual for use. The indicator of the new energy ...
View details -
Low temperature chilled lubricant selection considerations
2575When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
View details -
Tips for shutting down the industrial chiller for temperature control of the reactor
2011Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to...
View details
LNEYA Thermo Refrigeration Co.,Ltd