How does the ultra-low temperature test chamber control static electricity?
In order to control the static quality of the ultra-low temperature test chamber, the ultra-low temperature test chamber needs to control the static electricity better. How does the LNEYA ultra-low temperature test chamber control the static electricity?
Static electricity in the ultra-low temperature test chamber is caused by friction and separation between the items, so these factors need to be avoided as much as possible. For example, in the pipeline transportation or other operations, it is recommended to reduce the running speed, but this will affect the operating efficiency at the same time, so the more appropriate method is to use uninsulated insulation items, and choose materials that are not easy to generate static electricity.
In order to better control the static electricity, the generated electric charge can be grounded through the metal conductor, so that the generated electric charge disappears in the earth. If it is a charged body, it can be easily eliminated. If it is chemical fiber or petroleum, the charged part is charged. The charge is difficult to move, and this type of effect is not very effective.
The ultra-low temperature test chamber can add conductive properties to the article to cause electric charge leakage. This also includes the addition of metal powder to the tire or boots and the factory floor material of the operation, and the use of hydrophilic oil in the chemical fiber or plastic to prevent static electricity. Increasing the relative humidity in the air in the ultra-low temperature test chamber creates a water absorbing layer on the surface of the article to enhance conductivity. For this reason, in places where there is a possibility of electricity, it is possible to increase the humidity by adjusting the humidity device or sprinkling water. The problem is that people may feel uncomfortable or have an adverse effect on equipment and products.
The above description is to better help everyone to prevent some accidents, better improve the product quality of the ultra-low temperature test chamber, and better operate the equipment.
Related recommendations
-
Celebrate New Year’s Day and Welcome New Year
2342When the bells echo in the clear night sky,When the calendar turns to a new page,We are about to usher in a new year.Thanks for this year's harvestLet us have precious experience on our growthThere is always a reward for sweatThis yearWe sh...
View details -
What should be paid attention to when placing the thermostat system?
1988There are certain differences in the size and performance of the high and low temperature thermostat systems produced by different manufacturers. The user needs to pay attention to how it is placed when placing it after purchase, otherwise it will...
View details -
New energy shaft cooling chiller
1842New energy shaft cooling does not necessarily require industrial freezers, but is usually achieved using industrial chillers or cooling systems. Industrial freezers are mainly used for extremely low temperature freezing and processing, w...
View details -
Precautions for Leakage Inspection of Glycol Chiller
2749The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, ...
View details