How to install and use the reactor temperature control system?
Many users are going to start the installation after purchasing the reactor temperature control system. What should be paid attention to during installation?
When installing the reaction kettle of the reactor temperature control system, it is necessary to pay attention to whether the reactor is damaged during transportation and installation. The magnetic stirrer on the upper part of the kettle lid should be avoided, and the reaction of the reactor temperature control system should be avoided. The kettle operating room requires good ventilation and meets explosion protection requirements. The reaction kettle equipped with the reactor temperature control system was mounted on a support, and balanced on the four supports to keep the equipment perpendicular to the ground. Anti-static grounding devices should be installed on the flammable and explosive equipment of the reaction medium to eliminate static electricity.
If it is a high-temperature, high-speed magnetic stirrer, the reaction kettle equipped with the reactor temperature control system should be filled with lubricating oil at the bearing oil filling port before use. In the future use, the lubricating oil should be added regularly from the oil filling hole. The reactor equipment for the reactor temperature control system is supplied with cooling water in the outer water jacket of the magnetic stirrer before starting. The lower end is the water inlet and the upper end is the water outlet. A separate cooling water system should be used. The cooling water is not allowed. The cooling coil is then passed through the cooling coil in the kettle to enter the cooling water jacket of the magnetic stirrer.
The control cabinet and frequency converter of the reactor temperature control system equipment should be placed in a separate, electrically controlled workshop with dry and well ventilated. When the stirring speed of the reactor temperature control system equipment is greater than 80r/min, the motor cannot be started directly at the working speed, and the stirring speed should be slowly increased by the inverter. Otherwise, the stirrer resistance is too large, causing the magnetic stirrer to overload and causing the agitation to damage or burn the motor. The reaction kettle of the reactor temperature control system needs to be tested for tightness according to the working pressure. It is kept under inert gas for 15~30 minutes to check whether the whole equipment is leaking. If there is no leakage, it can be put into production.
When using the reactor temperature control system, it is necessary to pay attention to the switch is not suitable too much, so as not to damage the overall performance of the reactor temperature control system and the life of the fitting.
Related recommendations
-
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
2196LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
View details -
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
2159The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
View details -
Description of Type Selection and Classification of 40GW Cryogenic Chillers
2178If different enterprises and different industries have different requirements for Wuxi Guanya 40GW cryogenic chillers, its model selection is also different. So it is better to have a clear understanding of the needs of the selection of 40GW cryog...
View details -
What are the causes of corrosion in industrial chillers / water chillers?
2886Industrial chillers are now widely used in various industries, but as they become more and more widely used, many problems slowly emerge. Corrosion problems are also relatively common. Because everyone does not use the standard and the maintenance...
View details
LNEYA Thermo Refrigeration Co.,Ltd