반도체 패키징 및 테스트 분류 기계에 냉각기를 사용해야 하는 이유는 무엇일까요?
In the semiconductor packaging testing process, especially in the temperature control process of the sorting machine (test probe station), the use of chillers is mainly based on the following reasons:
Temperature stability and accuracy: The performance testing of semiconductor devices is extremely sensitive to temperature. Subtle temperature fluctuations will affect the accuracy of test results and the performance evaluation of the device. The chiller provides a stable low-temperature environment to ensure minimal temperature fluctuations during the test process, ensuring the repeatability and accuracy of test data.
열 관리: During the test process, especially high-power devices will generate a large amount of heat energy when running. The chiller can effectively take away this heat energy to prevent heat accumulation, keep the test equipment and DUT at a safe operating temperature, and avoid thermal stress damage to the equipment. Or affect the test accuracy.
Improve efficiency: The rapid cooling of the chiller can shorten the time for the device to cool to the test temperature and improve the test efficiency. Especially when multiple temperature cycle tests or rapid temperature changes are required, the efficiency of the chiller is more critical.
Protect devices: The chiller avoids large temperature fluctuations that may be caused by direct use of ambient temperature control, and protects sensitive semiconductor devices, especially new semiconductor materials or precision devices that are sensitive to temperature.
Environmental adaptability: The semiconductor testing environment requires constant temperature and humidity. The chiller is not affected by temperature changes in the external environment and can ensure a stable indoor testing environment even in extreme weather.
Extend the service life: By reasonably controlling the temperature, the chiller avoids overheating, expansion and contraction of the equipment, protects the equipment, and extends the service life of the test equipment.
In summary, the application of chillers in temperature control of semiconductor sealing, testing and sorting machines is a key technical means to ensure test accuracy, efficiency, protect equipment, improve product quality and environmental adaptability, and extend equipment life.
Semiconductor Cooling Chillers
FLT-100℃~90℃
주로 에칭 장비용으로 설계된 단일 채널 공랭식 쿨러입니다. 챔버 측벽에 독립적인 온도 제어를 제공하는 데 사용됩니다.
FLTZ -45℃~90℃
40 ℃ 이내의 가열 방식은 압축기 고온 가스 가열 완전 밀폐형 설계를 채택하고 기계는 24 시간 연속 작동 반도체 온도 제어 장치 칠러는 주로 ...
로딩 중...
이미 마지막 에피소드에 도달했습니다!
관련 권장 사항
-
반도체 제조 기업에 가열 서큘레이터 장비가 필요한 이유는 무엇일까요?
1124온도 제어 정확도: 반도체 제조 공정은 온도 제어에 대한 요구 사항이 매우 엄격합니다. 가열 순환기는 정밀한 온도 제어를 제공하여 온도가 일정하게 유지되도록 보장할 수 있습니다.
세부 정보 보기 -
열교환 냉각기 ETCU
3115온도 범위 : + 5 ℃ ~ 90 ℃ ± 0.3 ℃ 냉각 용량 : 5kw ~ 30kw 탱크 용량 : 6L ~ 15L 전력 : 06KW ~ 1.6KW 40 ℃ 이내의 가열 방식은 압축기 고온 가스 가열 완전 밀폐 설계를 채택하고 기계는 작동합니다 ...
세부 정보 보기 -
칩 테스트에 반도체 냉각기가 필요한 이유
472Struggling with chip test failures? See how semiconductor chillers keep wafers stable, cut downtime, and protect your production.
세부 정보 보기 -
FLT -45℃~40℃
1926Model FLT-402 FLT-402W FLT-403 FLT-403W FLT-404 FLT-404W FLT-406 FLT-406W FLT-408 FLT-408W FLT-410 FLT-410W FLT-415 FLT-415W Temp Control -45℃~40℃ Temp control accuracy ±0.1℃ Flow Control 10~25L/min 5bar max 15~45L/m...
세부 정보 보기