Hydraulic system cooling and heating temperature control system
The application of cooling and heating temperature control system in hydraulic system is very critical, especially in occasions where precise temperature control is required. This system can ensure that the hydraulic oil is kept within the required temperature range during operation, thereby improving the efficiency of the system and extending the service life of the equipment.
The following is a detailed description of a refrigeration and heating temperature control system with a temperature range of 20°C to 150°C and a working medium flow rate of 50L/min:
System requirements:
- Temperature range:
•Minimum temperature: 20°C
•Maximum temperature: 150°C
•Temperature control accuracy: ±1°C or higher is usually required
- Flow rate:
•Flow rate of working medium (hydraulic oil): 50L/min3.
Other requirements:
•Automation control
•Data recording and monitoring
•Safety protection measures
•Efficient energy saving.
Selection considerations
- Heating power calculation:
•Calculate the required heating power based on the flow rate and temperature rise requirements.
The formula is as follows:
Where: •(P) is the heating power (kW)
•(C_p) is the specific heat capacity of the hydraulic oil (kJ/kg·K)
•(m) is the flow rate (kg/s), which can be calculated by density and volume flow rate
- ▲ is the temperature rise (K)
- Calculation of cooling capacity:
- Calculate the required cooling capacity based on the flow rate and temperature drop requirements.
The formula is similar:
Where: •(Q) is the cooling capacity (kW)
•(C_p) is the specific heat capacity of the hydraulic oil (kJ/kg·K)
•(m) is the flow rate (kg/s)
- ▲ is the temperature drop (K)
- Pump selection:
- Select a pump suitable for hydraulic oil to ensure that its flow rate and pressure can meet the system requirements.
- Pipeline and valve selection:
- Select high temperature and corrosion resistant pipeline and valve materials to ensure long-term stable operation of the system.
Summary To design a refrigeration and heating temperature control system with a temperature range of 20°C to 150°C and a working medium flow rate of 50L/min, it is necessary to comprehensively consider the heating and cooling capacity, flow rate, temperature control accuracy and safety protection measures. By rationally selecting the heating unit, refrigeration unit, circulation pump, temperature control system and safety protection device, it is possible to ensure that the hydraulic system operates under ideal temperature conditions and improve the efficiency and reliability of the system. In the specific selection and design process, it is recommended to consult a professional equipment supplier or engineer to ensure the performance and safety of the system.
동적 온도 제어 시스템
SUNDI Z 주파수 변환 시리즈
WHATSAPP WECHAT Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion…
SUNDI -10℃~150℃
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Ultra high temperature cooling technology can directly cool from a hi…
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI-320/320W
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra-high Temperature Cooling Technology Can Directly Cool Down From 300℃ High Temperature. Bec…
SUNDI -25℃~200℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ ● 작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어...
SUNDI -45℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
SUNDI -60℃~250℃
Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with ox…
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
로딩 중...
이미 마지막 에피소드에 도달했습니다!