Refrigeration and heating temperature control system for aerospace vacuum heat sink testing
The application of refrigeration and heating temperature control system in aerospace vacuum environment heat sink testing is very critical. Such equipment is usually used to simulate thermal performance tests under extreme temperature conditions, aiming to simulate the thermal behavior of spacecraft in space environment, so as to evaluate the thermal management capability and reliability of aerospace equipment in space environment.
In the field of aerospace, refrigeration and heating temperature control systems are widely used to evaluate the performance and reliability of key components such as satellites, spacecraft, and rocket engines under extreme temperature conditions. Such equipment plays an irreplaceable role in ensuring that aerospace equipment can withstand the challenges of space environment.
The following are the specific applications and characteristics of refrigeration and heating temperature control system in aerospace vacuum environment heat sink testing:
Wide Temperature Range: The refrigeration and heating temperature control system can provide a wide temperature range from extremely low temperature (such as -180°C) to high temperature (such as 200°C), simulating extreme temperature changes in space environment.
Accurate Temperature Control: The equipment has high-precision temperature control capability, which can accurately adjust the temperature in the test chamber to ensure temperature stability and accuracy during the test.
Vacuum Environment Simulation: The test chamber can operate under vacuum conditions to simulate the low pressure conditions in the space environment to evaluate the thermal performance of aerospace equipment in a vacuum environment.
Heat Sink Test: The cooling and heating temperature control system can simulate the conditions of the heat sink, that is, simulate the process of heat exchange between the spacecraft and the cosmic background radiation in space through thermal radiation, which is used to evaluate the design performance of the spacecraft thermal control system.
Rapid Temperature Change: It can quickly switch between high and low temperatures, simulate the temperature changes of the spacecraft in the earth’s orbit and under the sun, and evaluate the thermal cycle performance of the equipment.
Data Recording and Analysis: It can automatically record the temperature data and other key parameters during the test, which is convenient for subsequent data analysis and evaluation of test results.
Safety and Protection: It has a variety of safety protection measures, such as over-temperature protection, over-current protection, etc., to ensure safety during the test.
Automated Testing: It is usually equipped with an automated control system, such as PLC or a more advanced automated system, to realize the programming, execution and monitoring of the test program, and improve the test efficiency and accuracy.
Scalability and Compatibility: The design takes scalability and compatibility into consideration, and can be integrated with a variety of test equipment, supporting a variety of test standards and protocols.
Durability and Maintenance: Durable materials and design are used, easy to maintain and maintain, ensuring long-term stable operation.
REFRIGERATION HEATING UNITS SUNDI 시리즈
SUNDI Z 주파수 변환 시리즈
왓츠앱 위챗 초고온 냉각 기술은 300℃의 고온에서 직접 냉각할 수 있습니다[팽창의 열전달 매체만 있기 때문에...
SUNDI -10℃~150℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120 ~ 350 ℃ ± 0.5 ℃ AC 380V 50HZ 8kW 최대 초고온 냉각 기술은 높은 온도에서 직접 냉각 할 수 있습니다 ...
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI-320/320W
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ 초고온 냉각 기술은 300℃ 고온에서 직접 냉각할 수 있습니다. Bec...
SUNDI -25℃~200℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ ● 작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어...
SUNDI -25℃~300℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI -45℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
SUNDI -60℃~250℃
초고온 냉각 기술은 300℃의 고온에서 직접 냉각할 수 있습니다[팽창 챔버의 열전달 매체만 산소와 접촉하기 때문에...
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
로딩 중...
이미 마지막 에피소드에 도달했습니다!
관련 권장 사항
-
-
ZLT HED 시리즈
3268이 장치는 화학 매체를 직접 도입하고 온도를 정확하게 제어할 수 있으며 화학 반응 전 매체의 예열, 예냉 및 온도 제어 역할을 합니다. 화학 매체에는 불화수소가 포함됩니다.
세부 정보 보기 -
Purchasing Strategy of Ultra-low Temperature Freezer
983The performance of refrigeration system determines the overall performance. If refrigeration technology is good, excellent refrigeration effect can be achieved quickly. It takes only 4-5 hours on average from room temperature to minus 8 degrees Ce...
세부 정보 보기 -
다양한 고압 반응기 구성을 갖춘 고저온 제어 시스템
858고압 원자로의 다른 구성, 다른 제조업체가 가져온 제품의 품질은 동일하지 않지만주의 사항은 동일하므로주의를 기울여야합니다. 1. 지정된 위치에서 사용하려면 ...
세부 정보 보기 -
폐쇄 순환 냉각 시스템 디버깅 주의 사항에 대한 자세한 설명
1214The preparation of the closed circulation cooling system before commissioning is an important part of the debugging process, which may affect the progress of the whole debugging process. Generally, attention should be paid to the leakage detection...
세부 정보 보기 -
Application and function of explosion-proof constant temperature circulation system
1014Temperature control in drug research and development and chemical experiments, as well as temperature control in small-scale experimental production and industrial production, all require highly dynamic constant temperature controllers. The chemic...
세부 정보 보기