유리 반응기에 순환 냉각기와 히터가 필요한 이유는 무엇인가요?
The common glass reaction vessels on the market can be divided into three categories: negative pressure glass reaction vessels, vacuum glass reaction vessels, and high-temperature and high-pressure stirred glass reaction vessels.
The glass reaction kettle mainly utilizes its double-layer glass characteristics. We can place reaction materials in the middle interlayer and stir the reaction under normal pressure or negative pressure. The glass reaction kettle injects a constant temperature hot solution or cooling liquid through the double-layer reaction kettle interlayer to heat or cool the materials inside the reactor at a constant temperature, and can provide stirring. In this way, the medium inside the interlayer of the glass reactor is stirred to perform a cyclic reaction, achieving heating or cooling effects. It is a commonly used biochemical instrument widely used in modern fine chemical, biopharmaceutical, scientific research and experimental industries. It can perform concentration, distillation, reflux, separation, and purification reactions under constant speed, force, and temperature conditions. It is an ideal instrument and equipment for teaching, experimentation, pilot testing, and production.
The double-layer glass reactor can provide high-temperature reaction (the maximum temperature can reach 300 ℃); The double-layer glass reactor can also perform low-temperature reactions (the minimum temperature can reach -80 ℃); A double-layer glass reactor can be evacuated to perform vacuum depressurization reactions. Its unique design makes the temperature control of the experiment more precise, ensuring that the experiment is conducted in a safer environment.
During experiments and production processes involving high or low temperature reactions, glass reaction vessels typically require a circulating chiller and heater to achieve precise temperature control.
The following situations explain why these two devices are needed:
Wide Temperature Range: When the reactor needs to operate over a wide temperature range, requiring both high-temperature reactions (such as up to 250 ℃ or above) and low-temperature reactions (as low as -80 ℃ or lower), it must be equipped with both a heater and a circulating chiller. A heater is used to heat the reaction medium, while a chiller is used for cooling to achieve the required reaction conditions.
High Temperature Control Accuracy: In experiments that require high temperature control accuracy, such as drug synthesis, fine chemical production, etc., the combination of circulating chillers and heaters can provide more accurate temperature regulation. Through closed-loop control systems, such as PID control, the temperature inside the reactor is maintained to have minimal fluctuations near the set value.
Continuous production or complex reaction processes: In complex reaction processes that require continuous production or involve multiple temperature stages, rapid response and precise adjustment of heating and cooling equipment have become particularly important. The integrated use of chillers and heaters can quickly adjust the temperature of the reaction vessel to meet the process requirements of different stages.
Thermal Management: A large amount of heat may be generated during the reaction process, and the chiller needs to remove excess heat in a timely manner to prevent overheating. At the same time, the heater can provide necessary heat supplementation in the early stage or low-temperature reaction stage.
Improving efficiency and product quality: Accurate temperature control can optimize reaction rate, improve product yield and purity. The combination of chiller and heater can significantly improve experimental or production efficiency and product quality.
RECIRCULATING CHILLERS
로딩 중...
이미 마지막 에피소드에 도달했습니다!
CHILLERS & HEATERS
SUNDI Z 주파수 변환 시리즈
왓츠앱 위챗 초고온 냉각 기술은 300℃의 고온에서 직접 냉각할 수 있습니다[팽창의 열전달 매체만 있기 때문에...
SUNDI -10℃~150℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120 ~ 350 ℃ ± 0.5 ℃ AC 380V 50HZ 8kW 최대 초고온 냉각 기술은 높은 온도에서 직접 냉각 할 수 있습니다 ...
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI-320/320W
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ 초고온 냉각 기술은 300℃ 고온에서 직접 냉각할 수 있습니다. Bec...
SUNDI -25℃~200℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ ● 작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어...
SUNDI -45℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
SUNDI -60℃~250℃
초고온 냉각 기술은 300℃의 고온에서 직접 냉각할 수 있습니다[팽창 챔버의 열전달 매체만 산소와 접촉하기 때문에...
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI -90℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
SUNDI -100℃~100℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
로딩 중...
이미 마지막 에피소드에 도달했습니다!
RECIRCULATING HEATERS
UST 시리즈
APPLICATIONS Suitable for temperature control in more usage scenariosUsed with reactors, reactors, microchannels, distillation systems, etc., and also used for heating and cooling of other equipment. Widely used in pharmaceutical, chem…
UC/LY Series Heating Circulators
APPLICATIONS Product Features Product Parameters APPLICATIONS Temperature control solution for Distillation and concentration The ba…
로딩 중...
이미 마지막 에피소드에 도달했습니다!
We provide stand alone Rotary Evaporators,Glass Reactors , choose your equipment, and choose your set up. Call or email us for more details.
관련 권장 사항
-
제약 생산의 반응기를 위한 통합 온도 제어 장치
928반응기 시스템은 통합 온도 제어 시스템과 효과적으로 협력하여 다양한 화학 반응 및 생산 공정의 온도 제어 요구 사항을 충족할 수 있습니다. 원자로 온도 제어 장비는 ...
세부 정보 보기 -
반응 주전자를 위한 온도 제어 시스템
843반응조 온도 제어 시스템은 화학, 제약, 생화학, 재료 과학 등의 분야에서 널리 사용되는 반응조 내부의 물질 온도를 정밀하게 제어하는 데 사용되는 자동화 장비입니다.
세부 정보 보기 -
-
SUNDI -10℃~150℃
2608완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120 ~ 350 ℃ ± 0.5 ℃ AC 380V 50HZ 8kW 최대 초고온 냉각 기술은 높은 온도에서 직접 냉각 할 수 있습니다 ...
세부 정보 보기