전체 방송국 검색

Battery cooler

KRY 0℃~100℃ double-channel chiller

Cooling capacity 2.5kW~38kW
순환 펌프 MAX
2~50L/min 2bar
Temperature accuracy ±0.3℃
Power AC380V/ AC460V

KRY 0~100 two-channel chiller, as a kind of battery cooler, owns two independent temperature control system. There are two lights at the top of the equipment. The equipment has two sets of systems. Temperature, pressure and flow rate can be controlled independently. The water cooled type adopts a tubular heat exchanger. The air water cooled type adopts the design of air outlet on the top. The equipment size is appropriately enlarged. The external circulation pipeline needs to be selected properly. Do not use artificial throttling pipelines, otherwise it will increase the load of the circulating pump. The pipelines need to be well insulated. Rubber insulation pipes with high temperature resistance can be adopted.

Battery cooler

0°C

최저

100°C

최고

±0.3°C

온도 제어 정확도


모델 KRY-25/2T KRY-55/2T KRY-75/2T KRY-A10/2T KRY-A15W//2T KRY-A25W/2T KRY-A38W/2T KRY-A60W/2T
온도 범위 0℃~+100℃
온도 제어 정확도 ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
유량 출력 2~20 L/min 2~25 L/min 2~25 L/min 2~25 L/min 2~25 L/min 2~25 L/min 5~50 L/min 5~50 L/min
유량 정확도 ±0.2 L/min
난방 용량 2.5kW*2 5.5kW*2 7.5kW*2 10kW*2 15kW*2 15kW*2 25kW*2 38kW*2
냉각 용량 100℃ 2.5kW*2 5.5kW*2 7.5kW*2 10kW*2 15kW*2 25kW*2 38kW*2 60kW*2
20℃ 2.5kW*2 5.5kW*2 7.5kW*2 10kW*2 15kW*2 25kW*2 38kW*2 60kW*2
5℃ 1.8kW*2 3.8kW*2 5.2kW*2 7kW*2 11kW*2 18kW*2 27kW*2 42kW*2
콘덴서(W) Paris/Shenshi tube type heat exchanger
콘덴서(A) Copper tube aluminum fin heat exchanger (upper outlet form)
전원 380V50HZ 9kW 19kW 23kW 29kW 34kW 52kW 80kW 120kW

온도 피드백k

온도 피드백 PT100(입구 온도, 출구 온도)


압축기

높은, 미쓰비시, 파나소닉 및 기타 압축기


통신 프로토콜

MODBUS RTU 프로토콜 RS485 인터페이스



  • The interior of pipeline:internal structure of the pipeline Lneya’s automotive chiller uses is made of stainless steel SUS304, copper, ceramic, silicon carbide, silicone sealant and PTFE.
  • Touch Screen: The multifunctional image display presents comprehensive important data information, such as data, lines and annotations. The operation safety status is continuously monitored and visualized on the touch screen.
  • Shell Material: uses cold-rolled sheet powder coating RAL7035. The color of our automotive chiller is a light greyish-brown tone, taking into account both the requirements for rust prevention and aesthetics.

KRY -40℃~100℃
battery chillers

water-cooling & air-cooling
Heating capacity 2.5kW~60kW
Cooling capacity 1.2kW~60kW
온도 정확도 ±0.3℃

KRYZ -40℃~100℃
부동액 쿨러

water-cooling & air-cooling
Heating capacity 2.5kW~38kW
Cooling capacity 1.8kW~60kW
온도 정확도 ±0.3℃

KRY -40℃~100℃ Multi-channel
액체 냉각 냉각기

water-cooling & air-cooling
Heating capacity 7.5kW~25kW
Cooling capacity 1.8kW~25kW
온도 정확도 ±0.1℃

KRYZ -40℃~50℃
배터리 팩 냉각 시스템

냉각 용량 0.5kW~10kW
난방 용량 0.5kW~10kW
온도 정확도 ±0.5℃


KRYO 0℃~160℃
오일 냉각기

Heating power 15kW~38kW
Cooling capacity 12kW~38kW
Flow rate accuracy ±0.2L/min
온도 정확도 ±0.3℃

신뢰할 수 있는 이동식 냉각기 공장

당사는 자체 공장과 온도 제어 분야에서 20년 이상의 경험을 보유한 매우 강력한 냉각기 공급업체입니다.

당사의 우수한 작업장 기술, 강력한 공장 제조 역량, 기술 지원 및 유지보수 서비스 범위: 빠른 냉각, 고효율 및 에너지 절약, 환경 보호 또는 온도 제어, 유량 제어, 압력 제어 등과 같은 기타 응용 시나리오가 필요한지 여부에 관계없이 당사는 풍부한 경험을 바탕으로 고객에게 가장 적합한 냉각기를 결정할 수 있도록 도와드립니다.

풍부한 경험과 걱정 없는 사전 판매 및 애프터 서비스를 통해 고객은 냉각기의 최적의 성능과 서비스 수명을 유지하는 데 탁월한 도움을 받을 수 있습니다. 이는 운영의 전반적인 성공과 효율성을 더욱 촉진합니다.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

적합한 냉각기를 찾을 수 없나요? 또는 냉각기를 선택하는 방법을 모르시나요? 지금 바로 문의하여 냉각기 세부 정보 및 가격을 알아보세요.

No. The parameters we present here are merely intended to give you an idea in your mind. The temperature control range that we can achieve is from -40℃ to 150℃. Additionally, we can customize according to your requirements.

This requirement can be achieved. Our professional R&D personnel will communicate with you to understand your need clearly. LNEYA is famous for non-standard customization. Leave your contact information and someone will get in touch with you soon ! LNEYA has always placed you first.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!