전체 방송국 검색

Aerospace Materials | Test Device Temperature Control

LNEYA has rich experience in product research and development in the aerospace industry, and provides a variety of cooling methods, including direct cooling, air cooling, and liquid cooling to meet different customer needs.

Products include: refrigeration heating temperature control systems, low-temperature chillers, direct cooling units, gas cooling chiller, test chambers

솔루션

항공우주 분야에서 소재의 성능은 항공기의 안전성, 신뢰성, 효율성과 직결됩니다. 과학과 기술의 발전으로 항공우주 소재에 대한 요구 사항은 특히 고온, 고압, 고속, 극미중력과 같은 특수한 환경에서 점점 더 높아지고 있습니다.
Therefore, how to accurately control the temperature through the test device to simulate and verify the performance of materials under these extreme conditions has become an important research direction.

동적 온도 제어 시스템SUNDI/SUNDIZ/HR&HRT
직접 냉각 냉각기Ultra-low Temperature Series
액체 냉각 냉각기저온 시리즈
Heating SystemsHR/HRT 시리즈
테스트 챔버
가스 냉각 냉각기LQ 시리즈

SUNDI 고정 주파수 시리즈

-온도 제어 정확도는 ±0.3℃에 달할 수 있습니다.

동적 온도 제어 시스템은 높은 온도 제어 정확도, 지능형 온도 제어 및 -120 ℃ ~ + 350 ℃의 넓은 온도 제어 범위를 갖추고있어 대부분의 회사의 항온 제어 요구에 적합합니다.

SUNDI 변수 빈도 시리즈

-20% 이상 에너지 절약

이전 모델에 비해 SUNDI 제품의 냉난방 순환 시스템은 가변 주파수 제어를 채택하여 20% 이상의 에너지를 절약하고 소음을 5 데시벨 이상 줄이며 시동 전류가 작습니다.

HR/HRT 시리즈

-비용 효율적인 경제 모델

온도 범위: -45℃~250℃, 난방 및 냉방 기능 포함, 전력은 3.5kW~15kW, 저전력 및 비용 효율적인 냉난방 시스템만 지원합니다.

ZLTZ High-efficiency heat exchange chiller

—Highly efficient heat exchange, automatic recovery of heat transfer medium

The ZLTZ temperature control unit is combined with the microchannel reactor to form a high exothermic temperature control application. Under the same flow rate conditions, the heat transfer efficiency is more than 5 times that of the heat transfer oil heat exchange control temperature control. At the same time, the inlet and outlet temperature difference is small, and the temperature field is highly uniform. It is particularly suitable for applications with violent exothermic reactions.

Learn

ZLJ/SLJ series direct cooling 냉각기

—Can be used for gas capture

The refrigerant in the refrigeration system is directly transferred to the target control element (heat exchanger) for heat exchange, thereby cooling the target control object. This system has a heat exchange capacity that is typically more than five times greater than that of a fluid (gas) being transferred to a heat exchanger. This makes it particularly suitable for applications where the heat exchanger has a small heat exchange surface but a high heat transfer capacity.

자세히 알아보기

LT 고정 주파수 시리즈

—Compressor cascade refrigeration, temp as low as -150℃

Temperature range from -150℃ to -5℃, using secondary supercooling technology, rapid cooling. Strong product reliability and excellent performance.

LTZ Variable 빈도 시리즈

—Adopt frequency conversion technology, high efficiency and energy saving

Adopt frequency conversion technology to achieve high efficiency and energy saving. The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user’s cooling and heating load requirements through the built-in frequency conversion device, thereby avoiding the compressor and electric heating full load confrontation, maintaining a stable working state of the unit and achieving energy-saving effects.

LTG Series Screw Chillers

—-110℃~30℃ freezing medium can be provided

It is suitable for various chemical, pharmaceutical, mechanical and other fields as a process cooling source. It can provide -110℃~30℃ refrigeration medium and can be used as a process cooling source required by ice storage, low-temperature ventilation and other production processes. The unit adopts advanced semi-hermetic screw compressor, which is low-carbon and energy-saving.

UST 시리즈

-미디어 온도 제어 정확도 ±0.5℃, 재료 온도 제어 정확도 ±1℃

고온 냉각 공정을 채택하여 300℃~50℃의 냉각 범위를 달성하고, 열교환 면적이 넓고 냉난방 속도가 빠르며 열전달 오일 수요가 상대적으로 적은 냉난방 일체형 용기를 장착하여 연속 냉난방을 실현할 수 있습니다.

UC/LY 시리즈

-+50℃ ~ +170℃, 중간 온도 제어 정확도 ±0.5℃만 지원

전체 사이클이 닫히고 고온에서 오일 미스트 휘발이 없으며 열전달 오일이 산화 및 갈변되지 않으며 내부 순환 온도 프로브 PT100을 보정하는 기능이 있습니다.

급속 온도 변화 테스트 챔버

-빠른 온도 변화, 빠른 가열 및 냉각 속도

환경 스트레스 스크리닝 테스트에 적용하여 제품의 환경 스트레스 스크리닝을 통해 제품 설계 결함 발견을 가속화하고 제품 신뢰성을 향상시킵니다. 많은 산업에서 고속 온도 변화주기 테스트를 통해 이미 생산 테스트 단계에 진입한 신뢰할 수 없는 시스템을 식별할 수 있다는 사실을 깨달았습니다. 이는 품질을 개선하고 제품의 정상적인 작동 수명을 효과적으로 연장하는 표준 방법이 되었습니다.

2도어 충격 테스트 챔버

-충격 테스트, 저온 -40~0℃ 고온 +60~+150℃

테스트 바스켓은 고온 및 저온 충격 테스트 중에 이동할 수 있습니다. 고온 및 저온 충격 변환은 주로 고온 영역과 저온 영역에서 테스트 바스켓을 위아래로 움직여 완료됩니다. 2박스 타입의 충격 회복 시간은 3박스 타입보다 짧습니다.

워크인 테스트 챔버

-온도 제어 범위: -80℃ ~ +150℃

저온, 고온, 고온 및 저온 변화, 일정한 습열, 고온 및 저온 교대 습열 및 기타 전체 기계 또는 대형 부품의 테스트에 적합합니다. 스튜디오의 크기와 기능은 사용자 요구 사항에 따라 변경할 수 있습니다. 블록형 상자는 다양한 고객의 요구를 충족시키기 위해 아름다운 모양과 과학적인 공기 덕트 디자인을 갖추고 있습니다.

LQ 시리즈

-저온은 -110℃까지 도달할 수 있습니다.

가스 냉각에 적용(비부식성): 건조 압축 공기, 질소, 아르곤 및 기타 상온 가스를 LQ 시리즈 장비에 도입하면 배출 가스가 목표 저온에 도달하여 테스트할 부품 또는 열교환기에 공급될 수 있습니다.