Aerospace Materials | Test Device Temperature Control
LNEYA has rich experience in product research and development in the aerospace industry, and provides a variety of cooling methods, including direct cooling, air cooling, and liquid cooling to meet different customer needs.
Products include: refrigeration heating temperature control systems, low-temperature chillers, direct cooling units, gas cooling chiller, test chambers
솔루션

항공우주 분야에서 소재의 성능은 항공기의 안전성, 신뢰성, 효율성과 직결됩니다. 과학과 기술의 발전으로 항공우주 소재에 대한 요구 사항은 특히 고온, 고압, 고속, 극미중력과 같은 특수한 환경에서 점점 더 높아지고 있습니다.
Therefore, how to accurately control the temperature through the test device to simulate and verify the performance of materials under these extreme conditions has become an important research direction.

SUNDI 고정 주파수 시리즈
—temperature control accuracy can reach ±0.3℃
Dynamic temperature control system has high temperature control accuracy, intelligent temperature control, and a wide temperature control range, from -120℃ to +350℃, which is suitable for most companies’ constant temperature control needs.

SUNDI Variable Frequency Series
—Energy saving of more than 20%
Compared with the old model, the cooling and heating circulation system of SUNDI products adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current.

HR/HRT Series
—Cost-effective economic model
Temperature range: -45℃~250℃, with heating and cooling functions; power only supports 3.5kW~15kW, low-power and cost-effective cooling and heating system.

ZLTZ 고효율 열교환기 그룹
-높은 효율의 열교환, 열 회수 가능
ZLTZ控温机组与微通道反应器组合成↪SHan_2FBC↩放热量控温运↪SHan_2F64↩,同流量↪SHan_2F2F↩况下相对导热油换热控温传热效率5倍以上,同时进出↪SHan_2F1D↩温差↪SHan_2F29↩,温度场均匀性↪SHan_2FBC↩,特别适合剧烈放热反应的应;。

ZLJ/SLJ系列直冷机
-몸집에 사용 가능
将制冷系统中的制冷剂直输出蒸发入⼊⽬标控件(换热器)换热,从⽽使标控对象降温。具备换热能力相对流体(⽓体)输送⼊换热器换热能⼒更⾼⼀般在5倍以上,这样特别适⽤于换热器换热⾯积⼩,但是换热量⼤的运场所。

LT 고정 주파수 시리즈
—Compressor cascade refrigeration, temp as low as -150℃
Temperature range from -150℃ to -5℃, using secondary supercooling technology, rapid cooling. Strong product reliability and excellent performance.

LTZ Variable Frequency Series
—Adopt frequency conversion technology, high efficiency and energy saving
Adopt frequency conversion technology to achieve high efficiency and energy saving. The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user’s cooling and heating load requirements through the built-in frequency conversion device, thereby avoiding the compressor and electric heating full load confrontation, maintaining a stable working state of the unit and achieving energy-saving effects.

LTG Series Screw Chillers
—-110℃~30℃ freezing medium can be provided
It is suitable for various chemical, pharmaceutical, mechanical and other fields as a process cooling source. It can provide -110℃~30℃ refrigeration medium and can be used as a process cooling source required by ice storage, low-temperature ventilation and other production processes. The unit adopts advanced semi-hermetic screw compressor, which is low-carbon and energy-saving.

UST 시리즈
—Media temp control accuracy ±0.5℃, material temp control accuracy ±1℃
The high-temperature cooling process is adopted to achieve a cooling range of 300℃~50℃; it is equipped with a heating and cooling integrated container with a large heat exchange area, a fast heating and cooling rate, and a relatively small demand for heat transfer oil; it can achieve continuous heating and cooling.

UC/LY 시리즈
—+50℃~+170℃, only supports medium temp control accuracy ±0.5℃
The entire cycle is closed, there is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned; it has the function of correcting the internal circulation temperature probe PT100.

급속 온도 변화 테스트 챔버
-빠른 온도 변화, 빠른 가열 및 냉각 속도
환경 스트레스 스크리닝 테스트에 적용하여 제품의 환경 스트레스 스크리닝을 통해 제품 설계 결함 발견을 가속화하고 제품 신뢰성을 향상시킵니다. 많은 산업에서 고속 온도 변화주기 테스트를 통해 이미 생산 테스트 단계에 진입한 신뢰할 수 없는 시스템을 식별할 수 있다는 사실을 깨달았습니다. 이는 품질을 개선하고 제품의 정상적인 작동 수명을 효과적으로 연장하는 표준 방법이 되었습니다.

2도어 충격 테스트 챔버
-충격 테스트, 저온 -40~0℃ 고온 +60~+150℃
테스트 바스켓은 고온 및 저온 충격 테스트 중에 이동할 수 있습니다. 고온 및 저온 충격 변환은 주로 고온 영역과 저온 영역에서 테스트 바스켓을 위아래로 움직여 완료됩니다. 2박스 타입의 충격 회복 시간은 3박스 타입보다 짧습니다.

워크인 테스트 챔버
-온도 제어 범위: -80℃ ~ +150℃
저온, 고온, 고온 및 저온 변화, 일정한 습열, 고온 및 저온 교대 습열 및 기타 전체 기계 또는 대형 부품의 테스트에 적합합니다. 스튜디오의 크기와 기능은 사용자 요구 사항에 따라 변경할 수 있습니다. 블록형 상자는 다양한 고객의 요구를 충족시키기 위해 아름다운 모양과 과학적인 공기 덕트 디자인을 갖추고 있습니다.

LQ 시리즈
-저온은 -110℃까지 도달할 수 있습니다.
가스 냉각에 적용(비부식성): 건조 압축 공기, 질소, 아르곤 및 기타 상온 가스를 LQ 시리즈 장비에 도입하면 배출 가스가 목표 저온에 도달하여 테스트할 부품 또는 열교환기에 공급될 수 있습니다.