전체 방송국 검색

Hydrogen chillers

HLTZ -40℃~-30℃

냉각 용량
4.5kW~40kW
냉매
R404A/R448A
Temperature accuracy ±0.3℃
Power AC380V/ AC460V

Hydrogen gas passes through an internal high-pressure heat exchanger, and the refrigeration system directly exchanges heat with hydrogen gas through refrigerant, achieving efficient heat exchange and temperature control.
The equipment body adopts a positive pressure explosion-proof system, and the positive pressure system is equipped with a thermostat to ensure that the system environment is maintained at room temperature.
Compared to traditional antifreeze or other fluids that exchange heat with hydrogen gas, this equipment uses refrigerant (phase change heat) as the medium for the refrigeration system, which has higher energy efficiency
Built in renewable dryer ensures internal dryness of the positive pressure system without condensation.
It can be combined with high-pressure microchannel heat exchangers or shell and tube heat exchangers (99Mpa) to form a heat exchange and temperature control unit.
The equipment adopts frequency conversion control, and the technical parameter table shows the cooling capacity under 50Hz working condition. When the frequency conversion is adjusted to 70Hz, the cooling capacity will also increase proportionally.

Hydrogen chillers

-40°C

최저

30°C

최고

±0.3°C

온도 제어 정확도


모델 HLTZ4-10WPEX HLTZ4-40WPEX HLTZ4-75WPEX
온도 범위 -40 ℃~-30℃ -40℃~-30℃ -40℃~-30℃
온도 제어 정확도 ±0.3℃ ±0.3℃ ±0.3℃
온도 피드백 Pt100 Pt100 Pt100
Cooling capacity 50HZ -40℃ 4.5kW 16kW 40kW
냉매 R404A/R448A
전원 공급 장치 380V 50HZ optional three-phase/460V 60HZ

온도 피드백k

온도 피드백 PT100(입구 온도, 출구 온도)


압축기

높은, 미쓰비시, 파나소닉 및 기타 압축기


통신 프로토콜

MODBUS RTU 프로토콜 RS485 인터페이스



LNEYA never disappoints users!

장점 Hydrogen Chillers

The chiller helps maintain the electrolyzer, reactor and other key components within the optimal operating temperature range by providing precise temperature control.

  • Directly exchange heat with hydrogen through refrigerant
  • Adopt positive pressure explosion-proof system, built-in constant temperature system
  • Built-in regenerable dryer to ensure dryness without condensation water

글리콜 칠러

난방 전력 3.5kW~15kW

temperature accuracy ±0.3℃

유체 냉각기

Heating power 2.5kW~10kW

temperature accuracy ±0.3℃

실험실 냉각기

Circulation Pump MAX 5m³/h~28m³/h 2bar

temperature accuracy ±0.5℃

영하 냉각기

Circulation Pump MAX 2.5m³/h~15m³/h 2bar

냉각수 칠러

Circulation Pump MAX 1.5m³/h~7.7m³/h 2bar

temperature accuracy ±0.5℃

공랭식 칠러

Circulation Pump MAX 2.4m³/h~12.1m³/h 2bar

temperature accuracy ±0.5℃

수냉식 칠러

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

temperature accuracy ±0.5℃

극저온 냉각기

Circulation Pump MAX 20L/min~40L/min 2bar

temperature accuracy ±0.5℃

신뢰할 수 있는 이동식 냉각기 공장

당사는 자체 공장과 온도 제어 분야에서 20년 이상의 경험을 보유한 매우 강력한 냉각기 공급업체입니다.

Our excellent workshop technology, strong factory manufacturing capabilities, and technical support and maintenance service coverage determine: whether you need fast cooling, high efficiency and energy saving, environmental protection, or other application scenarios such as temperature control, flow control, pressure control, etc., we have rich experience to help you determine the chiller that best suits you.

With rich experience and worry-free pre-sales and after-sales services, customers can trust us to provide unparalleled help to maintain the optimal performance and service life of the chiller. This further promotes the overall success and efficiency of their operations.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

적합한 냉각기를 찾을 수 없나요? 또는 냉각기를 선택하는 방법을 모르시나요? 지금 바로 문의하여 냉각기 세부 정보 및 가격을 알아보세요.

The Chiller System directly exchanges heat with hydrogen through the refrigerant to achieve efficient heat exchange and temperature control.

Safe(explosion-proof) and stable:
The equipment body adopts a positive pressure explosion-proof system, and the positive pressure system has a built-in thermostat to ensure that the system environment is maintained at room temperature.
Energy saving :
Compared with traditional antifreeze or other fluids and hydrogen heat exchange, this equipment uses the medium as the refrigeration system refrigerant (phase change heat), which is more energy efficient.
Easy to operate:
The refrigeration system is equipped with a 7-inch Siemens touch screen\PLC controller, which can realize PC remote control, communication functions, screen display and other operations, improving customer experience while ensuring safety.
Strong frequency conversion adjustment capability:
The equipment adopts variable frequency control. The technical parameter table shows the cooling capacity under 50hz working conditions. When the frequency conversion is adjusted to 70hz, the cooling capacity will also increase proportionally.
High voltage adaptability and system integration capabilities:
It can be combined with a high-pressure microchannel heat exchanger or a shell and tube heat exchanger (99Mpa) to form a heat exchange and temperature control unit.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!