Ultra-low Temperature Chillers

-150℃~-110℃ direct cooled chiller

ZLJ
ZLJ Series Cooling capacity
0.4kW~3.2kW
SLJ Series Cooling capacity 2.5KW~11KW
Temperature accuracy ±1℃
Power AC400V/ AC460V

The heat exchange capacity ishigher than that of the fluid (gas) transported into theheat exchanger, which is especially suitable for theapplication of the heat exchanger with a small heatexchange area, but a large heat exchange. lt can alsobe used as a gas trap, the refrigerant is directlyevaporated into the trap, and the gas in the space israpidly captured through the condensation effect onthe surface of the trap.

ZLJ & SLJ series

-150°C

최저

-15°C

최고

±1°C

온도 제어 정확도


모델 ZLJ-41
ZLJ-41W
ZLJ-43
ZLJ-43W
ZLJ-46
ZLJ-46W
온도 범위  -40℃~-15℃
온도 제어 정확도 ±1℃(Steady state outlet temperature)
Cooling capacityAT-35℃ 0.5kW 1.6kW 3.2kW
냉매 R404A 옵션 R507C R448
High temp cooling With high temp. 150℃direct cooling technology, to meet the goal of rapid cooling in high temp. operation
치수 cm 320*400*600 800*700*600 450*700*1350
회로 차단기 6A 6A 16A
모델 ZLJ-81
ZLJ-81W
ZLJ-83
ZLJ-83W
ZLJ-86
ZLJ-86W
온도 범위  -80℃~-50℃
온도 제어 정확도 ±1℃(Steady state outlet temperature)
Cooling capacity AT-70℃ 0.4kW 1.3kW 2.5kW
냉매 R404A/R508B
High temp cooling With high temp. 150℃direct cooling technology, to meet the goal of rapid cooling in high temp. operation
치수 cm 320*630*650 950*1000*800 550*1000*1750
회로 차단기 10A 16A 25A
모델 SLJ-3W SLJ-4W SLJ-6W SLJ-11W
온도 범위  -150℃~-110℃
Cooling capacity AT-120℃ 3kW 4kW 6kW 11kW
Cooling capacity AT-135℃ 2.5kW 3.3kW 5kW 9kW
냉매 LNEYA -150 mixed refrigerant
치수 cm 750*750*1750 750*750*1750 950*1000*2050 1300*2000*3500
회로 차단기 40A 55A 65A 100A

LNEYA never disappoints users!

장점 초저온 냉각기

LNEYA’s SLJ series direct cooler is an ultra low temperature chiller, specially designed to provide a solution for application scenarios that require extremely low temperatures. The minimum of temperature it can achieve is -150℃. In addition, the cooling mode of SLJ series direct coolers is limited to water cooling. Water cooling technology removes heat through circulating water flow, ensuring that the internal temperature of the equipment remains within the set range. This design not only improves the reliability of the equipment but also effectively reduces energy consumption during operation, making it an ideal choice for industrial environments with extremely stringent temperature requirements. At the same time, due to its design optimized for water cooling, you need to ensure adequate water supply and appropriate drainage facilities to support the normal operation of the system when installing and operating it.

thermal probe

Temperature Accuracy ±0.2℃

ultra low temperature chillers

temperature accuracy ±1℃

thermal chuck

temperature accuracy ±0.5℃

신뢰할 수 있는 이동식 냉각기 공장

당사는 자체 공장과 온도 제어 분야에서 20년 이상의 경험을 보유한 매우 강력한 냉각기 공급업체입니다.

Our excellent workshop technology, strong factory manufacturing capabilities, and technical support and maintenance service coverage determine: whether you need fast cooling, high efficiency and energy saving, environmental protection, or other application scenarios such as temperature control, flow control, pressure control, etc., we have rich experience to help you determine the chiller that best suits you.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

We are an industrial chiller manufacturer in China. Lneya is a technology-based enterprise focusing on the R&D and production of non-standard customized temperature control equipment. It is committed to providing products and solutions to your industry. Our service team has in-depth discussions with you about production processes, insists on being customer-oriented, and continuously invests resources in technological innovation and product iteration. We will be your reliable and promising collaborator. Contact us for further cordial cooperation.

*
*
제출하기....