전체 방송국 검색

기후 테스트 챔버

GD -80℃~+150℃

Cooling rate (No load) 125 ℃ → -40 ℃ 1 ℃/min (customizable for 5-25 ℃)
Heating rate (No load) -40 ℃ →+125 ℃ 1 ℃/min (customizable for 5-25 ℃)
Temperature uniformity ≤±1℃(unloaded)
에너지 소비량

The climatic test chamber provides an environment with high temperature, high humidity and high air pressure to accelerate the aging process of products, simulating the long-term aging situation of products in actual usage. It is a commonly used testing method in the chip industry. Through this testing method, the reliability and lifespan of chips can be inspected within a short period of time, thereby improving the quality and reliability of products.

-800°C

최저

150°C

최고


±1℃

온도 제어 정확도

매체 및 소재

Mode GD-518-2-C-DC
nside
 dimensions
(W*H*D)
Left cavity cm 60*124.5*65
Right cavity cm 60*124.5*65
온도 범위  -80℃~150℃
Heating rate (No load) -40 ℃ →+125 ℃ 1 ℃/min (customizable for 5-25 ℃)
냉각 속도 (No load) 125 ℃ → -40 ℃ 1 ℃/min (customizable for 5-25 ℃)
Temperature uniformity ≤±1℃(unloaded)
히터 Electric heating
Condenser(A) finned heat exchanger
Condenser(W) plate/sleeve/shell and tube heat exchanger
Outer box size (W*H*D) cm 409*236*175
전원 공급 장치 380V 50HZ

냉각 방법
Cascade refrigeration

Insulation material
Glass fiber cotton&polyurethane

Communication protocol interface
TCP/RS485 (CAN customizable)

높은 정밀도와 높은 효율성을 보장하는 열쇠

장점 기후 테스트 챔버


►The temperature control accuracy is around 0.1℃, the humidity accuracy is around 2.0%RH
►In the unloaded state, the temperature uniformity is around 1℃.
►Condenser: air cooled type uses finned tube heat exchanger, while water cooled type uses plate heat exchanger, shell-and-tube heat exhanger or shell-and-tube heat exchanger with jackets.
►Insulation material: glass fiber cotton or polyurethane
►Inner box material: SUS 304 stainless steel
►Utilizing long-shaft motors and stainless steel centrifugal fan blades for air circulation

battery test chamber

Heating power 6KW~15KW

Temperature uniformity ±1℃

climatic test chamber

Cooling rate Carrying idler (+20~-40℃)5℃/min

thermal shock chamber

High temperature +60~+150℃

Temperature fluctuation ≤1℃

신뢰할 수 있는 이동식 냉각기 공장

당사는 자체 공장과 온도 제어 분야에서 20년 이상의 경험을 보유한 매우 강력한 냉각기 공급업체입니다.

As a leader in refrigeration industry, LNEYA always attaches great importance to technological innovation. LNEYA has 90+ invention patents, and 20% of its 400+ employees are technicians. The production process adopts the Siemens PLM design platform to uniformly manage all data in the entire life cycle of the product from design, sales, production, after-sales to scrapping, to maximize the traceability of product quality.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

적합한 냉각기를 찾을 수 없나요? 또는 냉각기를 선택하는 방법을 모르시나요? 지금 바로 문의하여 냉각기 세부 정보 및 가격을 알아보세요.

A walk in environmental test chamber is a climate test chamber with large dimensions that users are able to enter. A walk in environmental test chamber, just like a constant climate chamber, simulates specific environmental conditions (temperature and relative humidity).

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!