Direct cooling Chiller

  • PLC & Touchscreen Interface
    Real-time monitoring, data logging and Ethernet connectivity
  • Multi-safety Protection
    Overheat cut-off, pressure alarms, and leakage prevention
  • Custom Solutions
    Adjustable voltage, refrigerant options(R404A, R508B, or LNEYA blends)
  • Fault-free operation time of over 100,000 hours.
  • High-efficiency performance and green environmental protection, industrial-grade reliability

thermal probe

Temperature Accuracy ±0.2℃

ultra low temperature chillers

temperature accuracy ±1℃

thermal chuck

temperature accuracy ±0.5℃

모델   ZLTZ-3
ZLTZ-3W
ZLTZ-6
ZLTZ-6W
ZLTZ-10
ZLTZ-10W
ZLTZ-15W ZLTZ-20W ZLTZ-30W ZLTZ-40W ZLTZ-75W ZLTZ-100W ZLTZ-150W
온도 제어    -10℃ ~25℃
냉각 용량 0℃에서 8.1kW 16.25kW 28.5kW 40.2kW 44.6kW 70.6kW 89.2kW 166.5kW 215kW 314.9kW
10℃에서 5.48kW 11kW 19.35kW 26.6kW 29.8kW 48.2kW 59.6kW 118kW 147.7kW 226.6kW
    11.9 23.6 41.8 58.1 70.9 106 127.8 220 314.7 411.2
인터페이스 크기 Drainage outlet φ12 φ12 φ28 φ28 φ28 φ28 φ42 DN50 DN50 DN65
Return water outlet φ20 φ20 φ35 φ35 φ42 φ54 φ54 DN80 DN80 DN100
Water-cooling at 25℃ 2m3/h 4m3/h 6.2m3/h 10m3/h 12.2m3/h 19m3/h 22m3/h 38m3/h 54m3/h 70.5m3/h
cooling water connector   G3/4 G1 DN32 DN40 DN40 DN50 DN65 DN80 DN100 DN100

모델   ZLTZ4-3
ZLTZ4-3W
ZLTZ4-6
ZLTZ4-6W
ZLTZ4-10
ZLTZ4-10W
ZLTZ4-15W ZLTZ4-20W ZLTZ4-30W ZLTZ4-40W ZLTZ4-75W ZLTZ4-100W ZLTZ4-150W
온도 제어    -40℃ ~20℃
냉각 용량 10℃에서 5.2kW 11.15kW 18.4kW 26.3kW 31.6kW 48.2kW 70.2kW 124.3kW 160.4kW 271.9kW
20℃에서 3.47kW 7.41kW 12.3kW 18.35kW 21.4kW 31.4kW 46kW 100.1kW 134kW 207.8W
30℃에서 2.24kW 4.81kW 7.92kW 11.8kW 12.67kW 19.16kW 28.2kW 68.3kW 90.4kW 142.3kW
40℃에서 1.36kW 2.95kW 4.7kW 5.83kW 6.74kW 10.45kW 15.41kW 42.8kW 55.2kW 89.3kW
    11.55 24.5 30.4 36.1 51.4 77.9 113.9 146.1 223.4 350.8
인터페이스 크기 Drainage outlet φ12 φ12 φ16 φ22 φ22 φ28 φ28 DN50 DN50 DN65
Return water outlet φ22 φ22 φ35 φ35 φ35 φ54 φ54 DN80 DN80 DN100
Water-cooling at 25℃ 2m3/h 4.2m3/h 5.3m3/h 6.2m3/h 9m3/h 14m3/h 20m3/h 31m3/h 38.5m3/h 60m3/h
cooling water connector   G3/4 G1 DN32 DN32 DN40 DN50 DN65 DN65 DN80 DN100

모델   ZLTZ8-3
ZLTZ8-3W
ZLTZ8-6
ZLTZ8-6W
ZLTZ8-10
ZLTZ8-10W
ZLTZ8-15W ZLTZ8-20W ZLTZ8-30W ZLTZ8-40W ZLTZ8-75W ZLTZ8-100W ZLTZ8-150W
온도 제어    -80℃~ -30℃
냉각 용량 30℃에서                    
40℃에서 6.9kW 14.8kW 24.4kw 36.7kW 42kW 73.2kW 110kW 187.5kW 257.5kW 365kW
60℃에서 3.3kW 7.1kW 12kW 17.4kW 20kW 35kW 52.5kW 89.3kW 122.5kW 173.8kW
75℃에서 1.65kW 3.55kW 6kW 8.7kW 10kW 17.5kW 26.2kW 44.7kW 61.3kW 87kW
인터페이스 크기 Drainage outlet φ12 φ12 φ16 φ22 φ22 φ28 φ28 DN40 DN40 DN65
Return water outlet φ22 φ22 φ35 φ35 φ35 φ54 φ54 DN80 DN80 DN100
Water-cooling at 25℃ 2.7m3/h 5.3m3/h 6.68m3/h 9.3m3/h 12.5m3/h 27.6m3/h 33.8m3/h 66.8m3/h 70m3/h 125m3/h
cooling water connector   G3/4 DN32 DN32 DN40 DN50 DN65 DN80 DN100 DN100 DN150

모델 ZLJ-41
ZLJ-41W
ZLJ-43
ZLJ-43W
ZLJ-46
ZLJ-46W
온도 범위  -40℃~-15℃
온도 제어 정확도 ±1℃(Steady state outlet temperature)
Cooling capacityAT-35℃ 0.5kW 1.6kW 3.2kW
냉매 R404A 옵션 R507C R448
High temp cooling With high temp. 150℃direct cooling technology, to meet the goal of rapid cooling in high temp. operation
치수 cm 320*400*600 800*700*600 450*700*1350
회로 차단기 6A 6A 16A

모델 ZLJ-81
ZLJ-81W
ZLJ-83
ZLJ-83W
ZLJ-86
ZLJ-86W
온도 범위  -80℃~-50℃
온도 제어 정확도 ±1℃(Steady state outlet temperature)
Cooling capacity AT-70℃ 0.4kW 1.3kW 2.5kW
냉매 R404A/R508B
High temp cooling With high temp. 150℃direct cooling technology, to meet the goal of rapid cooling in high temp. operation
치수 cm 320*630*650 950*1000*800 550*1000*1750
회로 차단기 10A 16A 25A

모델 SLJ-3W SLJ-4W SLJ-6W SLJ-11W
온도 범위  -150℃~-110℃
Cooling capacity AT-120℃ 3kW 4kW 6kW 11kW
Cooling capacity AT-135℃ 2.5kW 3.3kW 5kW 9kW
냉매 LNEYA -150 mixed refrigerant
치수 cm 750*750*1750 750*750*1750 950*1000*2050 1300*2000*3500
회로 차단기 40A 55A 65A 100A

모델 MD-708 MD-712 MDL-708
온도 범위 -75℃~225℃ -75℃~225℃  -75℃~225℃
온도 제어 정확도 ±0.5℃(정상 상태 출구 온도)
플레이트 온도 균일성 ±1℃ ±1℃ ±1℃
플레이트의 평탄도 ±15um ±15um ±15um
플레이트 크기 직경 200mm 디스크 직경 300mm 디스크 150mm*200mm
호스트 및 카드 연결 케이블 2.5m(다른 길이는 사용자 지정 가능)
평평한 표면 처리 니켈 도금(금도금 옵션)
난방  -60°C ~ +25°C: 2분
0°C ~ +25°C: 2분
+25°C ~ +220°C: 6분
냉각 220°C ~ +25°C: 2분
+25°C ~ -60°C: 6분
제어 시스템 PLC 컨트롤러, 난방 피드포워드 PID 퍼지 알고리즘, 냉각 전자 팽창 밸브 PID
조절 제어 냉각 용량
표시 및 기록 7인치 컬러 터치 스크린, 곡선 온도 및 알람 기록
커뮤니케이션 이더넷 인터페이스, TCP/IP 프로토콜
압축기 테쿰세
장비 치수mm 550*650*370 550*650*370 550*650*370

DIRECT COOLING CHILLER’S APPLICATIONS

It is generally used for machine cooling and spindle cooling in the production process, temperature control of various drugs and preparation processes in the pharmaceutical field, and temperature control of chemical reactions such as chemical or laboratory crystallization and synthesis, as well as new energy vehicle testing and semiconductor .

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

Direct cooling means that the cooling water is in direct contact with the back face of the target material that is being sputtered from the front face. Indirect cooling is where the water cools a metal plate and the target material is in contact with the cooled plate.

The commonly used compressors at LNEYA are screw-type and scroll-type.
Screw-type chillers are primarily used in central air conditioning systems or large-scale industrial refrigeration. Scroll-type chillers, on the other hand, have smaller power compared to screw-type chillers and may not be suitable for heavy-duty applications.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!

아래 QR 코드를 통해 계정 관리자를 추가하세요