Application of Industrial Air-Cooled Chiller in Chemical Industry
Industrial air-cooled chillers are applicable to glass reactors, metal reactors and bioreactors for temperature control. In the field of chemistry and pharmacy, air-cooled chillers usually carry out necessary temperature control together with the chemical reaction of the material itself. Through the temperature change of circulating medium in sheath or coil, the temperature control of materials and the target process temperature of materials can be realized.
For the temperature control of stroke water cooler in pharmaceutical industry, the requirements for selecting temperature control equipment are relatively high. Compared with the common temperature range of – 60 ℃ – 100 ℃, a wider working temperature range is required. At the same time, different chemical reactions require different temperature curves, and the high-temperature and low-temperature integrated units need to work at any different temperature point within this temperature range.
The high and low temperature integrated device for temperature control of air-cooled chiller adopts electric heating, which can quickly increase the temperature of circulating medium. It adopts energy-saving design to realize the regulation of refrigeration capacity, accurately control the temperature of materials, realize the endothermic or rapid response to exothermic of materials, and meet the drug production needs of most industrial occasions.
The characteristics of explosion-proof air-cooled chiller are as follows:
(1) The cascade compression refrigeration cycle of the refrigeration unit can reach a lower temperature. Electric heating can quickly increase the temperature of the circulating medium.
(2) The adjustment of refrigerating capacity change is realized. The refrigerant flow is mainly controlled by PID, and the material temperature is accurately controlled. The traditional method is to use electric heating to offset the cooling of the compressor, which wastes energy.
(3) The combined control of heating and cooling realizes the rapid response to the heat absorbed or released by the material.
(4) The control of material temperature is mainly realized by refrigerant flow control. The refrigerant proportional control valve adopts the valve body of electronic expansion valve. Higher temperature control accuracy can be achieved.
The temperature control of air-cooled chiller consists of refrigeration cycle system, heating cycle system and automatic control system. For areas where the equipment has explosion-proof requirements, the positive pressure explosion-proof cabinet can be customized, which not only meets the explosion-proof requirements, but also reduces the number of explosion-proof parts and reduces the production cost of the whole machine.
관련 권장 사항
-
What Is The Effect Of Small Water Cooled Chiller On Industrial Production?
1189The small water cooled chiller is used in a wide range of applications, such as the food processing industry and the pharmaceutical processing industry. In some industrial fields, small water cooled chillers are often required. The application of ...
세부 정보 보기 -
Operating Instructions For the Low Temperature Test Chamber
1147The low temperature test chamber is a necessary test equipment in aviation, automobile, household appliances, scientific research and other fields. It is used to test and determine the parameters and performance of electrical, electronic and other...
세부 정보 보기 -
약 60p 냉장 냉각기 에너지 소비가 너무 큼
139360p 냉장 냉각기의 성능은 제조업체마다 다르며 에너지 소비량도 다릅니다. 60p 냉장 냉각기의 에너지 소비가 너무 많으면 제때에 확인하여 확인해야합니다.
세부 정보 보기 -
LNEYA의 재순환 냉각기 사용 시 주의사항
1185LNEYA's low temperature recirculating chillercan be used with supporting instruments (such as rotary evaporators,fermentation tanks, chemical reactors, freeze-drying equipment,biopharmaceutical reactors, etc.), with large cooling capacity and f...
세부 정보 보기