What should I pay attention to when placing high and low temperature closed loop circulators?
There are certain differences in the size and performance of high and low temperature fully enclosed circulators from different manufacturers. Users need to pay attention to the placement position when placing them after purchase. If the placement position is not good, it is not conducive to the operation of high and low temperature fully enclosed circulators.
In the installation of high and low temperature fully enclosed circulators, the heat dissipation efficiency of the high and low temperature closed loop circulators should be considered and the maintenance should be easy. The floor of the equipment must be flat and have sufficient strength (3.4 N/m2 or higher). Select a dust. And locations where vibration effects are small.
High and low temperature fully enclosed circulators are to be installed in a dry room with a high and low temperature fully enclosed circulator, and where there is a power supply and sewer nearby, the equipment should be installed in a place with little dust. The wind condition causes no oxygen deficiency to occur even if the refrigerant (fluorohydrocarbon) leaks from the equipment.
Good ventilation should be maintained around the installation of high and low temperature fully enclosed circulators. During operation, the device will radiate heat. If it is air-cooled, it will directly discharge heat through the condensed air. In the case of small room and poor ventilation, the indoor temperature will rise rapidly, causing the machine to stop running and alarm. . Installation of high and low temperature fully enclosed circulators should be kept away from flammable or explosive materials or other substances that may generate high heat.
When placing it, be careful not to let the sun directly project onto the device. When the device is used beyond this range, the safety device will start or the device will stop running. In order to achieve stable performance of the high and low temperature closed loop circulator, the installation room of the high and low temperature closed loop circulator should be air-conditioned to maintain the indoor temperature between 10 ° C and 30 ° C.
The atmospheric environment of the high and low temperature fully enclosed circulator installation site is consistent with the general indoor air-conditioned atmospheric environment. If organic solvents, plasticizers, acids, alkalis or other chemicals are present in the air, the parts or coatings of the equipment may be corroded and destroyed.
The precautions for placing the high and low temperature fully enclosed circulators should be taken seriously by our operators. Read the instruction manual in detail.
Related recommendations
-
How to solve the fault of the ultra-low temperature refrigerator pressure controller?
2592If the industrial ultra-low temperature refrigerator encounters a controller-related failure during operation, if it is not resolved in time, the pressure controller may be unavailable. The pressure controller plays a very important role in the ul...
View details -
Matters Needing Attention in Replacing Refrigerant Oil of the Screw Chiller Factory
1967The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller fa...
View details -
Operating Instructions For the Low Temperature Test Chamber
2187The low temperature test chamber is a necessary test equipment in aviation, automobile, household appliances, scientific research and other fields. It is used to test and determine the parameters and performance of electrical, electronic and other...
View details -
How to check the cooling effect of industrial refrigerators?
1893For the user, how to check the cooling effect of the industrial refrigerator is an important part. LNEYA adopts a single-machine self-cascading refrigeration system. The environmentally friendly refrigerant and refrigeration effect users have a de...
View details
LNEYA Thermo Refrigeration Co.,Ltd












