Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to judge whether the compressors of small water cooled chillers are working properly and its daily maintenance methods.
1. Regularly check the operation status of the compressor equipment to check the exhaust gas temperature, especially when changing seasons. If the temperature difference is too large, it may affect the operation of the machine. If it is abnormally viewed in time, adjust the system condensation temperature and liquid supply status.
2. For small water cooled chiller equipment, it is also necessary to check the turbidity of the cooling water regularly and replace it if necessary.
3. Check whether the pump is working normally, check the running, dripping and leaking of the water supply system.
4. The refrigeration oil and filter of the chiller are replaced once every six months under normal conditions, depending on the usage.
Small water cooled chillers should be checked about the oil return of the compressor regularly in the later work, and keep it clean. When the oil level is reduced, it is necessary to replace the new oil in time to prevent the machine from being damaged due to poor lubrication.
Related recommendations
-
Laboratory Polymerization Reactor Water Cooling Chiller
1777Laboratory Polymerization Reactor Water Cooling Chiller is a device used to accurately control the temperature inside the reactor, especially for polymerization reactions that need to be carried out under specific temperature conditions. This equi...
View details -
Fault Hint of Cryogenic Chiller Refrigeration System
1905When the high and low pressure of the system are higher than normal, there is usually air or excessive refrigerant in the system. At this time, we need to re-vacuum, and then add a proper amount of refrigerant to solve this problem. But there are ...
View details -
Do You Know How to Save Electricity in Low Temp Freezer?
2169The name of low temp freezer should be known to all, that is, the temperature inside the cabinet will be very low, so since the temperature is low, the relative power consumption is more. So under such circumstances, how can we save electricity? A...
View details -
Maintenance of vacuum pump for fully enclosed heating and cooling circulator
2272Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump? For the f...
View details