Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to judge whether the compressors of small water cooled chillers are working properly and its daily maintenance methods.
1. Regularly check the operation status of the compressor equipment to check the exhaust gas temperature, especially when changing seasons. If the temperature difference is too large, it may affect the operation of the machine. If it is abnormally viewed in time, adjust the system condensation temperature and liquid supply status.
2. For small water cooled chiller equipment, it is also necessary to check the turbidity of the cooling water regularly and replace it if necessary.
3. Check whether the pump is working normally, check the running, dripping and leaking of the water supply system.
4. The refrigeration oil and filter of the chiller are replaced once every six months under normal conditions, depending on the usage.
Small water cooled chillers should be checked about the oil return of the compressor regularly in the later work, and keep it clean. When the oil level is reduced, it is necessary to replace the new oil in time to prevent the machine from being damaged due to poor lubrication.
Related recommendations
-
Description of power consumption in LNEYA large refrigeration unit
2508In the process of operation, the cooling capacity and working conditions will affect the power consumption of the entire large refrigeration unit, but in order to avoid unnecessary power consumption, we need to understand the other power consumpti...
View details -
Introduction to heating cooling temperature control system of fermentation tank
2277In the pharmaceutical and biochemical industry, the fermentation tank needs to be equipped with a heating, cooling and temperature control system to control the temperature in the system. The LNEYA refrigeration, heating, cooling and temperature...
View details -
Industrial grade heating and cooling system placement attention
2345Industrial-grade heating and cooling system Before the power is turned on, check whether the voltage specified on the nameplate is the same as the household voltage. The same can be used to arrange separate power lines and special sockets for the ...
View details -
-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
1892In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintena...
View details
LNEYA Thermo Refrigeration Co.,Ltd