How to install -50 °C cryogenic unit manufacturers equipment?
-50 °C cryogenic units are used in the refrigeration and chemical industry, so what issues should be paid attention to during installation? LNEYA professional manufacturers tell you that you should install according to the instruction manual.
For the -50 °C cryogenic unit compressor (unit) that has been tested at the factory and is protected by rust-proof seals and has good pre-installation protection measures, it can be directly installed, the protection measures are invalid, or the compressor (unit) has obvious defects. Check it and install it after confirming that it meets the factory manufacturer’s factory standards.
-50 °C cryogenic unit compressor (unit) should check the position of the foundation and anchor bolt holes before it is in place, it should meet the requirements of the design documents; it should be installed in the foundation and bracket according to the connection method required by the design and equipment technical documents. Welding shall not be used on hangers and on the design and equipment technical documentation. The installation should meet the requirements of the equipment technical documents. When leveling is required, the horn should be used. The installation should keep the body stable and should not exceed the inclination angle of the technical documentation of the equipment. Do not invert.
-50 °C cryogenic unit compressor (unit) manufacturer to ensure that the compressor does not corrode after leaving the factory and before use, no impurities, more inert gas for sealing treatment, so as long as the seal is intact, no obvious defects can be directly installation. For small, lightweight-50-degree cryogenic unit compressors (units), manual handling can be carried out during the installation process. Due to exceeding the limit angle or inversion, internal irreparable damage may occur, so standard handling is required. Refrigeration auxiliary equipment such as intercooler, gas-liquid separator, oil separator, liquid receiver, low-pressure circulating reservoir, oil collector, chiller, condenser, etc. in the refrigeration system shall be installed in accordance with current standards.
-50 °C cryogenic unit manufacturer Wuxi Guanya (LNEYA) will be arranged at the factory, the corresponding instructions to follow the equipment, the user can install according to the instructions.
Related recommendations
-
Description of the compressor of the high and low temperature damp heat test device
2330Different types of compressors for high and low temperature damp heat test devices often have an impact on price. When choosing, we should choose low-energy refrigeration compressors as much as possible. Now China is paying more and more attention...
View details -
Function of Evaporator in Air Cooled Chiller
2012The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
View details -
What type of temperature control system is required for smear preparation in the pharmaceutical industry?
1983In the pharmaceutical industry, negative pressure drying and smear preparation have specific requirements for temperature control, and usually require precise and adjustable temperature control devices to ensure product quality and process sta...
View details -
Ultra-low temperature freezing manufacturer analyzes the cause of blockage in refrigeration system
2436With the continuous development of technology, ultra-low temperature refrigeration technology is also constantly developing, and manufacturers are also increasing. Of course, the technology of different manufacturers is different. Once the refrige...
View details
LNEYA Thermo Refrigeration Co.,Ltd