How to install -50 °C cryogenic unit manufacturers equipment?
-50 °C cryogenic units are used in the refrigeration and chemical industry, so what issues should be paid attention to during installation? LNEYA professional manufacturers tell you that you should install according to the instruction manual.
For the -50 °C cryogenic unit compressor (unit) that has been tested at the factory and is protected by rust-proof seals and has good pre-installation protection measures, it can be directly installed, the protection measures are invalid, or the compressor (unit) has obvious defects. Check it and install it after confirming that it meets the factory manufacturer’s factory standards.
-50 °C cryogenic unit compressor (unit) should check the position of the foundation and anchor bolt holes before it is in place, it should meet the requirements of the design documents; it should be installed in the foundation and bracket according to the connection method required by the design and equipment technical documents. Welding shall not be used on hangers and on the design and equipment technical documentation. The installation should meet the requirements of the equipment technical documents. When leveling is required, the horn should be used. The installation should keep the body stable and should not exceed the inclination angle of the technical documentation of the equipment. Do not invert.
-50 °C cryogenic unit compressor (unit) manufacturer to ensure that the compressor does not corrode after leaving the factory and before use, no impurities, more inert gas for sealing treatment, so as long as the seal is intact, no obvious defects can be directly installation. For small, lightweight-50-degree cryogenic unit compressors (units), manual handling can be carried out during the installation process. Due to exceeding the limit angle or inversion, internal irreparable damage may occur, so standard handling is required. Refrigeration auxiliary equipment such as intercooler, gas-liquid separator, oil separator, liquid receiver, low-pressure circulating reservoir, oil collector, chiller, condenser, etc. in the refrigeration system shall be installed in accordance with current standards.
-50 °C cryogenic unit manufacturer Wuxi Guanya (LNEYA) will be arranged at the factory, the corresponding instructions to follow the equipment, the user can install according to the instructions.

관련 권장 사항
-
반도체 수냉식 온도 제어 플랫폼의 스로틀 구성 요소
1227반도체 수냉식 온도 제어 플랫폼의 스로틀링 구성 요소는 냉동 시스템에 없어서는 안 될 네 가지 주요 구성 요소 중 하나입니다. 그 기능은 고압 액체 컴프레서의 압력을 낮추는 것입니다.
세부 정보 보기 -
Simulation analysis and result analysis of battery pack thermal management
1088battery pack thermal management simulation analysis
세부 정보 보기 -
How To Solve The Electric Vehicle Motor Test Condensation Is Too High?
1153The condensing pressure of the electric vehicle motor test will increase, the compression function will increase, the cooling capacity will decrease, the cooling coefficient will decrease, and the energy consumption will increase. The reason for t...
세부 정보 보기 -
주사 전자 현미경 냉각수 순환 시스템
1138주사 전자 현미경(SEM)은 재료 과학, 생물학, 나노 기술 및 기타 분야에서 널리 사용되는 고해상도 현미경입니다. SEM은 작동 중에 일정량의 열을 발생시킵니다. 안정적인 작동을 보장하기 위해 ...
세부 정보 보기