Maintenance of Glycol Cooling Heating Control System
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.
Related recommendations
-
Application and function of explosion-proof constant temperature circulation system
2028Temperature control in drug research and development and chemical experiments, as well as temperature control in small-scale experimental production and industrial production, all require highly dynamic constant temperature controllers. The chemic...
View details -
How to prevent the freezing pressure of the bearing quick freezing box from being too low?
2246In the refrigeration system of the bearing blast chiller, if the condenser installation is not in the enclosed space, the system's exhaust pressure (condensation pressure) tends to be lower in winter (or low temperature), which is often more commo...
View details -
Test of working temperature of electric vehicle power battery
2079The normal working temperaturerange of power batteries for electric vehicles is -30 ~ 52 ° C, and the workingtemperature range is -46 ~ 66 ° C, which is difficult to achieve with existingpower batteries. Although local warming measures can be u...
View details -
Tips for shutting down the industrial chiller for temperature control of the reactor
1981Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to...
View details