Semiconductor heating and cooling thermostat compressor fault detection instructions
In the semiconductor heating and cooling thermostat, the compressor is one of its core components. Once it fails, it will affect the operation of the whole system. How to solve the fault is better?
The faults of semiconductor heating and cooling thermostat compressors can be divided into motor faults and mechanical faults (including crankshafts, connecting rods, pistons, valve plates, cylinder head gaskets, etc.). Mechanical failure often causes the motor to overload or even stall, which is one of the main causes of motor damage.
The compressor motor load includes the load required to compress the gas and the load required to overcome the mechanical friction. If the pressure ratio is too large, or the pressure difference is too large, the compression process will be more difficult; the frictional resistance caused by the lubrication failure will increase, and the motor stall in extreme cases will greatly increase the motor load. Lubrication failure and increased frictional resistance are the primary causes of load anomalies.
The short circuit caused by the metal shavings of the compressor, the metal chips trapped in the windings are the main culprit for the short circuit and the low grounding insulation value. The normal vibration of the compressor during operation and the twisting of the winding by the electromagnetic force at each start-up will promote the relative motion and friction between the metal chips interposed between the windings and the winding enameled wire. Sharp edges and swarf can scratch the enameled wire insulation and cause a short circuit.
Compressor contactor problems, contactors can meet demanding conditions such as fast cycling, continuous overload and low voltage. They have a large enough area to dissipate the heat generated by the load current, and the choice of contact material prevents soldering at high currents such as startup or stall. In order to be safe and reliable, the compressor contactor must simultaneously disconnect the three-phase circuit. The method of disconnecting the two-phase circuit is not recommended.
The rated current of the compressor contactor must not be lower than the rated current on the compressor nameplate. Contactors with small specifications or poor quality cannot withstand compressor start-up, large current surges during stalling and low voltage, and are prone to single-phase or multi-phase contact jitter, soldering or even falling off, causing motor damage.
Semiconductor heating and cooling thermostat compressors may have more faults. It is not recommended for users to solve them themselves. It is recommended to contact the manufacturer for after-sales service.
Related recommendations
-
Three integrated thermal shock test chamber cooling method
2387The three integrated thermal shock test chambers are designed and manufactured according to user requirements. They are suitable for high and low temperature impact tests of high-temperature or low-temperature environments and for high-temperature...
View details -
What should I do if there is noise from industrial cooling and heating chillers?
2335The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of tr...
View details -
Explosion-proof ultra-low temperature refrigerator internal leakage instructions
23381. Sound leak detection method: First, the refrigeration pipeline of the explosion-proof ultra-low temperature refrigerator is filled with nitrogen. Then use a stethoscope to check the interior. When you hear a leak in a certain area, mark it. Car...
View details -
Where can industrial heating circulators be useful?
2370The industrial heating circulator can provide a circulation device of cold source and heat source, and has a wide working range. It is used in the pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reac...
View details