Heating and cooling cycle machine maintenance boot operation instructions
When users choose the heating and cooling cycle machine, they often have to choose the right conditions for their own work, and their knowledge of maintenance and start-up also needs our attention.
After the installation of the heating and cooling cycle machine, the pipeline cleaning and sewage discharge, pressure test leak detection, air release, cooling water and chilled water system trial operation shall be carried out. After all normal operation, the unit commissioning and operation, cooling water and freezing shall be started. The water should be treated with water. The high alkaline water quality will intensify the corrosion of the copper tube and reduce the service life of the heat exchanger. The pH of the system water should be in the range of 7.0 to 8.5.
Press the “SET” button on the heating and cooling cycle thermostat once, the display shows the current thermostat set value. At this time, press the up and down triangular arrow buttons on the thermostat to adjust the thermostat set value and adjust. After that, press the “SET” button to confirm the new thermostat setting. note. The freezing water temperature cannot be set too low. If the temperature is too low, the cooling efficiency of the unit will be lowered, and the low temperature protection action alarm may be stopped. The water temperature may be set to be slightly lower than the required temperature. Set the water temperature according to actual needs.
After the heating and cooling cycle machine is turned on, the unit is equipped with an index of observable high and low pressure gauges with high and low pressure gauges, and the unit is operating normally. The normal operating pressure of high pressure is 12-18 Kg/cm2. The low pressure is 3 to 6 kg/cm2. Start up should see if the steering of the fan is correct, such as forward rotation can be started, reverse rotation means that the power supply wiring is reversed, and the phase sequence must be replaced before starting. The setting values of various protection devices have been set up by the factory. Do not change it at will.
When the heating and cooling cycle unit has a fault alarm and stops, first press the stop button of the unit (the alarm light will go out), and then check the cause of the fault. Do not force the machine to run before the fault is eliminated. If it is not an emergency, the unit should not be turned off by cutting off the main power supply; if the unit is stopped for a long time in the winter, turn off the unit first, then turn off the main power supply, and drain the water in the system.
To keep the heating and cooling cycle machine clean and well ventilated, periodically clean and remove the condenser to ensure normal and stable operation of the unit. To keep the cooling tower clean, and to keep the air flowing around the tower, the temperature is low, to prevent debris from entering the cooling tower to reduce heat dissipation efficiency. Air-cooled type Please keep the surface of the cooling water machine heat-dissipating coil clean, ensure the surrounding air circulation, low temperature, regularly clean the scale on the coil to ensure good heat transfer. If the cooling water machine has been in use for more than six months, or if the high/low pressure switch is frequently malfunctioning or the cooling capacity is reduced, please arrange for the staff to clean the condenser. If the repair is repeated according to the above instructions, the alarm of the cooling water machine is still {长鸣}, then the staff should be arranged for repair.
LNEYA is a high-tech enterprise that produces and sells technology. It provides refrigeration and heating solutions for pharmaceutical chemical research users. Its heating and cooling cycle machine will provide certain after-sales service after leaving the factory.
Related recommendations
-
Precautions for safe use of heat transfer oil temperature control equipment
2136With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temp...
View details -
Organic waste gas purification condensation shutdown note
2481If the organic waste gas is purified and condensed, if it encounters a fault during operation, it should be shut down and disposed of in time. Then, how can LNEYA organic waste gas purification and condensation be used once it is shut down? The or...
View details -
Low temperature cooling system exists in drying and freeze-drying equipment
1718In the drying and freeze-drying equipment, the low-temperature cooling system is one of the core components, which is crucial for achieving the freeze-drying process. Freeze drying (freeze-drying) is an effective method for removing moistu...
View details -
Laboratory crystallization water chiller
1833Laboratory crystallization water chiller is a device specially used in laboratory environment to control the temperature conditions during crystallization. This equipment is mainly used in the research and development process of chemistr...
View details