How to Solve the Problem of Compressor Noise in Industrial Low Temperature Chiller?
In industrial 저온 냉각기, compressor operation will produce noise, but only the
difference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?
Generally speaking, compressor noise must first understand the causes of its noise, in order to better deal with. The main reasons are: the compressor is not fixed well; compressor quality problems; compressor load is too large; compressor power supply is abnormal, running time is too long and other reasons. Understanding these reasons and solutions can make better use of industrial 저온 냉각기 compressors.
For the industrial 저온 냉각기 that have just started to use, if the noise is too big, it may be caused by the compressor not fixed properly when it is assembled. The fixing of the industrial 저온 냉각기 is fixed on the chiller bracket by the compressor foot. It must be fixed properly to ensure the normal operation noise of the compressor of the industrial cryogenic water chillers.
If it is not the fixed problem of compressor, it may be the compressor quality problem of industrial 저온 냉각기. In the production of industrial 저온 냉각기, Wuxi Guanya adopts brand compressor, which guarantees a little more quality.
If it is not fixed and quality problems, it may also be that the compressor load is too large, which will also restrict the operation of the compressor. The compressor load is too large is the larger reason for the compressor running noise. When the load rate exceeds 80%, there will be various problems.
If the power supply of industrial 저온 냉각기 is not normal, if the current and voltage are not working properly, noise will be produced. Only the normal current can ensure the normal operation of the compressor of industrial 저온 냉각기.
Another point is that the long running time of industrial 저온 냉각기 will also affect the life of their compressors. The wear and tear of internal bearings or axle boxes of industrial 저온 냉각기 will cause greater noise of compressors. It is suggested that the compressors should be replaced or maintained.
Industrial 저온 냉각기 is widely used in industry, so the above failures should be solved in time to avoid affecting the production process of users.
관련 권장 사항
-
기밀성을 갖춘 LNEYA의 300,000kcal 공랭식 장치
1154사용자가 300,000kcal 공냉식 냉각 장치를 작동하는 경우 기밀성으로 인해 공냉식 냉각 장치가 너무 많은 에너지를 소비 할 수 있으므로 기밀성을 확인해야합니다. 장시간 온도가 떨어지는 것을 방지하기 위해 ...
세부 정보 보기 -
The selection and maintenance of ultra-low temperature chiller
952Today, a customer came to inquire about our need for a small laboratory water chiller. The specific working condition is to reduce the materials in the 20L stainless steel reactor from normal temperature to minus 30 ℃ in more than one hour. This p...
세부 정보 보기 -
에틸렌 글리콜 저온 냉각기의 설치 요구 사항
1048에틸렌 글리콜 냉동 냉각기를 전문 제조업체인 우시 구야에서 구입한 후 설치 요구 사항이 장비와 함께 사용자의 손에 전달됩니다. 따라서 에틸렌 글리콜을 설치하는 동안주의해야 할 사항은 무엇입니까?
세부 정보 보기 -
Maintenance of high and low temperature circulator in the pharmaceutical industry
950The high and low temperature circulator in the pharmaceutical industry is also an increasingly common temperature control equipment in all walks of life. It is inevitable that the equipment needs to be maintained after long-term use. How to mainta...
세부 정보 보기