Cooling method for laboratory evaporative instruments in operation
Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When purchasing a suitable cooling water circulator, important factors to consider include: 1. Minimum condensing temperature and corresponding cooling capacity; 2. Circulating pressure; 3. Circulating flow rate; 4. Suitable accessories.
When selecting and setting the temperature of the cooling water cycle machine, it is generally recommended to follow the “Rule of 20”, that is, set a temperature difference of 20°C between the heating pot temperature and the steam temperature, and between the steam temperature and the condenser temperature. The lower the temperature that the cooling water circulation machine can provide, the better the condensation effect. The cooling water cycle machine usually has the maximum cooling capacity at 20°C or normal temperature, that is, the maximum cooling power parameter under ideal conditions, which is often the nominal cooling power marked by the manufacturer.
Our LNEYA cooling water circulator will provide cooling capacity of 20°C and 10°C, and different power supply will also be provided for model selection reference. It adopts international brand compressor, user-friendly design, stable performance and continuous work, flexible and convenient operation, multiple fault alarms and start-up delay protection, and the most important thing is that it is guaranteed to run continuously 24 hours a day.
If you also need temperature control of laboratory instruments, you can contact us for solutions. Email: sales@lneya.com
I hope to hear from you soon.

Related recommendations
-
Efficient method for extracting total cannabinoids using a cryogenic process cooling system
2366Although cannabis plants have been used for medicinal purposes for thousands of years, modern science has identified steroids, flavonoids and more than 100 therapeutically active compounds known as cannabinoids. Due to the significant synergy betw...
View details -
Recrystallization temperature and influencing factors?
1875Recrystallization is the process of recrystallizing crystals from a solution or melt after they are dissolved in a solvent or melted. Recrystallization can purify impure substances or separate mixed salts from each other. Among them it is the r...
View details -
High and low temperature device related instrument maintenance instructions
2075The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
View details -
Cooling method for semiconductor testing chiller to meet temperature control requirements
2890The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...