How is the refrigerant installed in the vocs condensing unit?
The vocs condensing equipment is LNEYA’s equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated?
For various refrigeration and heating equipment, generally there are many types of refrigerants, mainly freon, unsaturated hydrocarbon refrigerant, saturated hydrocarbon refrigerant, inorganic compound refrigerant, azeotropic mixture refrigeration. These kinds of agents, etc., generally use environmentally friendly R404 or R22 refrigerant, so you can rest assured when using, do not worry about refrigerant pollution.
In general, vocs condensing equipment generally has two methods when installing refrigerant. One is to use the compressor to remove the valve through hole and directly inject the refrigerant liquid into the system. This method is relatively fast and safe, and is more suitable for filling in the system when it is vacuumed and there is no refrigerant. This method uses the pressure difference and height difference between the refrigerant in the cylinder and the system to discharge into the refrigeration system. Once the filling is insufficient, it can be changed to the suction side. Once it is filled on the high pressure side, Be careful not to start the compressor to avoid accidents.
Another method is to fill the suction port of the compressor suction valve. When using this method, pay attention to the compressor of the vocs condensing device. When filling the liquid, remember to start the compressor and not inject the liquid refrigerant. In order to avoid liquid shock in the vocs condensing equipment. This method is suitable for situations where the system is insufficiently filled and needs to be added.
Need to know more to run vocs condensing equipment, LNEYA’s own vocs condensing equipment, welcome everyone to buy.
Related recommendations
-
Chiller for heat deflection temperature instrument
2145Temperature range: The temperature of the cooling water is usually required to be between 6 ℃ and 18 ℃.Temperature difference requirement: The temperature difference of the cooling water should be controlled within 0 ℃ or ± 0.5 ℃ to ensure precise...
View details -
Why is There Frost Phenomenon in the Low Temperature Chiller Circulator?
2243Many low temperature chiller circulators will frost when they are used, but there is no frost phenomenon in low temperature chiller circulators. So, what's the matter? Is it related to refrigeration? First of all, why does the low temperature chil...
View details -
Selection and installation of the expansion valve for recirculating chillers
2075Regarding today's topic, we have the following analysis. The selection of expansion valve plays an important role in the performance of the recirculating chiller refrigeration system. The correct choice of expansion valve will maximize the use o...
View details -
Semiconductor diffusion furnace configuration temperature control equipment
2216In the semiconductor industry, a diffusion furnace is a device used to manufacture doping layers on the surface of semiconductor materials. It achieves the doping process through high-temperature heating and controlled diffusion atmosphere. The di...
View details