As we all know, the low temperature chiller is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the lowest temperature of the low temperature chiller can only reach – 40 degrees. The main reason is limited by the limit operating conditions of single-stage piston compressor. If the evaporator temperature of the chiller is too low, the following problems will arise when it exceeds the limit operating conditions.
If the low temperature chiller is excessively refrigerated, it will have a great impact on the use function of the low temperature chiller product itself. The actual compression process deviates from the equal compression process to a great extent. The compressor gas transmission coefficient of the chiller decreases, and the compressor gas transmission capacity will be greatly reduced. This is very disadvantageous to the service life of the low temperature chiller products.
If the low temperature chiller is over-refrigerated for a long time, the influence on the compressor inside the low temperature chiller can not be ignored. When the compressor is over refrigerated, the exhaust temperature of the compressor is too high, and the lubricating oil on the cylinder surface of the compressor becomes thinner, which makes the lubricating condition worse. It may even cause the carbonization of lubricating oil, the phenomenon of cylinder pulling and the improper sealing of valve plates.
Related recommendations
-
Which Type of Chiller Can Be Chosen for Cooling XRD?
2341Which Type of Chiller for Cooling XRD?
View details -
Closed cycle heating system temperature deviation description
2050If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time. In the steady state, the closed loop heating system displays th...
View details -
How to solve the problem of poor cooling performance of the heat transfer oil circulation system?
2180Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user's power supply and whether the equipment is norm...
View details -
Water Distiller Circulating Chiller
1837Water distillers generate a lot of heat during operation, especially when they need to run continuously or process a large amount of water. In order to ensure that the water distiller can operate stably and maintain efficient distillation efficien...
View details
LNEYA Thermo Refrigeration Co.,Ltd