전체 방송국 검색

KRY Frequency Conversion Series

KRY 주파수 변환 시리즈

애플리케이션

Adopt variable frequency scroll compressor, automatically adjust the operating speed according to actual needs, provide the required cooling capacity, compared with traditional fixed frequency compressor, significantly reduce energy consumption and improve energy efficiency performance.

KRY -40 ℃~+135 ℃

 

모델 KRYZ-475
KRYZ-475W
KRYZ-4A15W KRYZ-4A25W
온도 범위 -40℃~+100℃ -40℃~+100℃ -40℃~+100℃
온도 제어 정확도 ±0.1℃ ±0.1℃ ±0.1℃
Temp feedback Pt100 Pt100 Pt100
Temp display 0.01k 0.01k 0.01k
유량 출력 1~25 L/min 1~25 L/min 1~25 L/min
유량 정확도 ±0.1 L/min ±0.1 L/min ±0.1 L/min
난방 전력 7.5kW 15kW 25kW
냉각
용량
100℃ 7.5kW 15kW 25kW
20℃ 7.5kW 15kW 25kW
0℃ 7.5kW 15kW 25kW
-20℃ 4.5kW 10kW 16kW
-35℃ 1.8kW 4kW 6.5kW
연결 크기 G3/4 G3/4 G3/4
Water-cooled At20℃ 2500L/H
ZG3/4
4000L/H
ZG1
6000L/H
DN32
전원 380V50HZ 14kW 25kW 38kW
치수 cm 55*85*175 70*100*175 80*120*185
무게 280kg 360kg 620kg
선택 사항 Extended to -40 ℃~+135 ℃

 

T: 2 groups of temperature/pressure/flow can be independently controlled

 

모델 KRYZ-475W/2T KRYZ-4A15W/2T KRYZ-4A25W/2T
온도 범위 -40℃~+100℃
온도 제어 정확도 ±0.1℃ ±0.1℃ ±0.1℃
Temp feedback Pt100 Pt100 Pt100
Temp display 0.01k 0.01k 0.01k
유량 출력 1~25 L/min 1~25 L/min 1~25 L/min
흐름 제어 정확도/그룹 ±0.1 L/min ±0.1 L/min ±0.1 L/min
Number of fuid output groups 2 groups 2 groups 2 groups
Pressure control/group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
난방 전력 7.5kW*2 10kW*2 15kW*2
냉각
용량
100℃ 7.5kW*2 15kW*2 25kW*2
20℃ 7.5kW*2 15kW*2 25kW*2
0℃ 7.5kW*2 15kW*2 25kW*2
-20℃ 4.5kW*2 8.5kW*2 14kW*2
-35℃ 1.8kW*2 4kW*2 6.5kW*2
Water-cooled At20℃ 4000L/H
ZG1
8000L/H
DN32
12000L/H
DN40
치수 cm 80*120*185 100*150*185 200*145*205
전원 380V50HZ 28kW 45kW 70kW
무게 660KG 850kg 1350kg
선택 사항 Extended to -40 ℃~+135 ℃
Hourly power consumption kWh -40℃ -10℃ 20℃
KRY-475 5 6.2 8.4
KRYZ-475 2.2 4 4.8
Frequency conversion saves power consumption 56% 35% 43%
Explain 1. Empty load test data; 2. The test condition is an ambient temperature of 20 ℃; 3. Flow rate 15L/min

 

Get more details

 

 

애플리케이션

New energy vehicle component verification temperature control solution

There are many applications. Typical application areas include research, testing and quality control of power batteries and new energy motors; it can also be applied to environmental simulation, material testing, and temperature-related stress and load testing of materials, transmissions, bearings and engine parts.


Since our founding in 2006, we have served over 30,000 customers and hold several patents that demonstrate our innovation and reliability. Our chillers are selected for over 100 university laboratory projects worldwide and exported to over 20 countries. We ensure the highest quality through a rigorous 3-step quality control process: visual inspection, performance testing, and electrical safety testing. Our commitment to excellence is further backed by our 24/7 customer support commitment. In addition, we have agents in the United States, Canada, Australia, Russia, and South Korea, making us a global, trusted partner for your chiller needs. Choose lneya for quality and support for your project.
18+

Years of experience

30000+

Satisfied Customers

25000

m² Production Area

80+

Patented Technologies

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!