전체 방송국 검색

ZLTZ High-efficiency Heat Exchange Chiller

ZLTZ 고효율 열교환 냉각기

애플리케이션

ZLTZ series temperature control unit is combined with cold plates and heat sinks to achieve high heat absorption and high uniformity temperature control. The ZLTZ temperature control unit is combined with ESC chucks, vacuum chucks, etc. to achieve a temperature control range of -65℃~200℃. At the same time, one ZLTZ temperature control unit can be used with multiple ESC chucks to control different temperatures.

Suitable for use in microchannel reactors, plate heat exchangers, cold plates, heat sink plates, tubular reactors and other places with small heat exchange area, large cooling capacity and small temperature difference. The ZLTZ temperature control unit is combined with a microchannel reactor to achieve high heat release temperature control. The equipment can automatically recycle the heat transfer medium. Under the same flow rate, the heat transfer efficiency of the heat transfer oil is more than 5 times higher. At the same time, the inlet and outlet temperature difference is small, and the temperature field is highly uniform, which is particularly suitable for applications with violent exothermic reactions.

모델 ZLTZ-3
ZLTZ-3W
ZLTZ-6
ZLTZ-6W
ZLTZ-10
ZLTZ-10W
ZLTZ-15W ZLTZ-20W ZLTZ-30W ZLTZ-40W ZLTZ-75W ZLTZ-100W ZLTZ-150W
온도 범위  -10℃ ~25℃
냉각 용량 0℃에서 8.1kW 16.25kW 28.5kW 40.2kW 44.6kW 70.6kW 89.2kW 166.5kW 215kW 314.9kW
10℃에서 5.48kW 11kW 19.35kW 26.6kW 29.8kW 48.2kW 59.6kW 118kW 147.7kW 226.6kW
인터페이스 크기 Export φ12 φ12 φ28 φ28 φ28 φ28 φ42 DN50 DN50 DN65
Return φ20 φ20 φ35 φ35 φ42 φ54 φ54 DN80 DN80 DN100
Water cooling at 25℃ 2m3/h 4m3/h 6.2m3/h 10m3/h 12.2m3/h 19m3/h 22m3/h 38m3/h 54m3/h 70.5m3/h
냉각수 인터페이스 G3/4 G1 DN32 DN40 DN40 DN50 DN65 DN80 DN100 DN100

 

모델 ZLTZ4-3
ZLTZ4-3W
ZLTZ4-6
ZLTZ4-6W
ZLTZ4-10
ZLTZ4-10W
ZLTZ4-15W ZLTZ4-20W ZLTZ4-30W ZLTZ4-40W ZLTZ4-75W ZLTZ4-100W ZLTZ4-150W
온도 범위  -40℃ ~20℃
냉각 용량 10℃에서 5.2kW 11.15kW 18.4kW 26.3kW 31.6kW 48.2kW 70.2kW 124.3kW 160.4kW 271.9kW
20℃에서 3.47kW 7.41kW 12.3kW 18.35kW 21.4kW 31.4kW 46kW 100.1kW 134kW 207.8W
30℃에서 2.24kW 4.81kW 7.92kW 11.8kW 12.67kW 19.16kW 28.2kW 68.3kW 90.4kW 142.3kW
40℃에서 1.36kW 2.95kW 4.7kW 5.83kW 6.74kW 10.45kW 15.41kW 42.8kW 55.2kW 89.3kW
인터페이스 크기 Export φ12 φ12 φ16 φ22 φ22 φ28 φ28 DN50 DN50 DN65
Return φ22 φ22 φ35 φ35 φ35 φ54 φ54 DN80 DN80 DN100
Water cooling at 25℃ 2m3/h 4.2m3/h 5.3m3/h 6.2m3/h 9m3/h 14m3/h 20m3/h 31m3/h 38.5m3/h 60m3/h
냉각수 인터페이스 G3/4 G1 DN32 DN32 DN40 DN50 DN65 DN65 DN80 DN100

 

 

 

모델 ZLTZ8-3
ZLTZ8-3W
ZLTZ8-6
ZLTZ8-6W
ZLTZ8-10
ZLTZ8-10W
ZLTZ8-15W ZLTZ8-20W ZLTZ8-30W ZLTZ8-40W ZLTZ8-75W ZLTZ8-100W ZLTZ8-150W
온도 제어  -80℃~ -30℃
냉각 용량 30℃에서
40℃에서 6.9kW 14.8kW 24.4kw 36.7kW 42kW 73.2kW 110kW 187.5kW 257.5kW 365kW
60℃에서 3.3kW 7.1kW 12kW 17.4kW 20kW 35kW 52.5kW 89.3kW 122.5kW 173.8kW
75℃에서 1.65kW 3.55kW 6kW 8.7kW 10kW 17.5kW 26.2kW 44.7kW 61.3kW 87kW
인터페이스 크기 Drainage outlet φ12 φ12 φ16 φ22 φ22 φ28 φ28 DN40 DN40 DN65
Return water outlet φ22 φ22 φ35 φ35 φ35 φ54 φ54 DN80 DN80 DN100
Water-cooling at 25℃ 2.7m3/h 5.3m3/h 6.68m3/h 9.3m3/h 12.5m3/h 27.6m3/h 33.8m3/h 66.8m3/h 70m3/h 125m3/h
cooling water connector G3/4 DN32 DN32 DN40 DN50 DN65 DN80 DN100 DN100 DN150

애플리케이션

신소재 | 특수가스 생산 온도 제어

API | 중간 생산 온도 제어 솔루션

증류 농도 온도 제어 솔루션

자세히 알아보기

자세히 알아보기

LNEYA has a large chiller production workshop equipped with CNC lathes and more advanced chiller manufacturing and processing machines.
lneya uses reliable international brand material accessories, Siemens controllers, Taikang compressors, etc. You can expect our chillers to provide precise temperature control and the best results.
Get A Quote

Contact LNEYA
*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!