전체 방송국 검색

Reactor Temperature Control System

WTD -45℃~+250℃

Cooling capacity 1.5kW~5.5kW
Heating power 5.5kW
Medium temp accuracy ±0.3℃
에너지 소비량

The WTD reactor temperature control system series has a temperature range of -45℃~+250℃. It is a device that integrates refrigeration, heating and temperature control functions. The product temperature control range is from -45 to 250℃.

This chiller heater unit optimizes temperature sampling and response speed, and the temperature control accuracy can reach ±0.3℃. It also supports dual-channel temperature control and can display the temperature of 2 groups of inlet and outlet liquids.

Reactor Temperature Control System parameter

-45°C

최저

250°C

최고


±0.3℃

온도 제어 정확도

매체 및 소재


모델 WTD-255-2T  Double Temp range
WTD-255W-2T  Double Temp range
WTD-455-2T  Double Temp range
WTD-455W-2T  Double Temp range
온도 범위 -25°C~200°C    -45°C~250°C  
Temp resolution 0.1K
Control panel 7 inch colorful touch screen
데이터 곡선 Data Curve Record
Date output U 디스크 엑셀 형식
Control model PID Adaptive controller
난방 용량 5.5kW 5.5kW 5.5kW 5.5kW
냉각 용량 kW 250°C     5.5kW 5.5kW
200°C   5.5kW 5.5kW 5.5kW 5.5kW
100°C 5kW 5kW 5 kW 5kW
20°C 5kW 5kW 5 kW 5kW
-15°C 2 kW 2 kW 4 kW 4kW
-35°C     1.5kW 1.5kW
최대 순환 펌프 25L/min 3bar    Double Line 25L/min 3bar   Double Line
Cooling way Air cooled + Water cooled Air cooled + Water cooled
냉매 R404A R404A
Metal insulated hose 1.8M*4 1.8M*4
치수 cm 70*100*175 70*100*175
전원 380V 50HZ 19kW  MAX 20kW  MAX

장점 Reactor Temperature Control System


 
Reduce refrigerant consumption
WTD reactor temperature control system adopts fully enclosed pipeline design, and the internal flow channel is compact. Under the premise of ensuring the cooling effect, it can reduce the amount of refrigerant charged and reduce operation and maintenance costs.
 
냉각 방법
WTD reactor temperature control system provides two cooling methods: air cooling and water cooling. The evaporator used is a plate heat exchanger with higher heat exchange efficiency.

Reactor Temperature Control System 애플리케이션

The WTD reactor temperature control system can keep the temperature in the reactor within the ideal range. Therefore, it is an important auxiliary equipment for microchannel reactors. At present, the WTD reactor temperature control system has been widely used in the fields of medicine, chemical industry etc.


 

Reactor Temperature Control SystemS related

chiller manufacturer in china

글로벌 서비스

30,000 +customers.
20+ countries.

인증 특허

CE ,SGS, ISO certification.

판매 후 서비스

24/7 solutions.

전문 팀

15+ years experience.

품질 관리

Quality test.

자주 묻는 질문

현장 보증 수리 및 반품 보증 수리 서비스를 제공합니다. 간편하고 빠른 교체 프로세스와 연중무휴 서비스 접수로 생산 효율과 사용자 경험에 영향을 주지 않습니다.

물론이죠. 당사의 맞춤화 범위에는 공정 냉각기 히터의 유형, 크기, 온도, 전력, 쉘 재질, 순환 펌프, 방폭, 제어 시스템, 데이터 통신 인터페이스, 입구 및 출구 크기, 컬러 터치 스크린 크기 등이 포함되지만 이에 국한되지 않습니다.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!