Factors affecting cooling capacity during temperature control of battery test equipment
Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher the cooling capacity, the lower the water temperature, the smaller the cooling capacity. Battery test equipment pump power water circulation amount, directly affects heat transfer speed, evaporator, condenser form, divided into water tank coil test, shell tube type, stainless steel plate type, etc., we need to configure according to certain requirements, thermal material Medium copper tube heat transfer is better.
There are also external factors affecting the cooling capacity of battery test equipment. Most of the battery test equipment is air-cooled. Therefore, the external ambient temperature needs to be within a reasonable range. The condensation temperature should not exceed 45 degrees. Once the cooling capacity is exceeded, it will be significantly weakened. Can not be too low, the battery test equipment air is also very important for convection, the vents can not have a barrier, reference to the standard outlet vents can not have obstacles within 1 meter.
The cooling capacity of the battery test equipment is related to the operation process of the entire battery test equipment. Therefore, the cooling capacity of the battery test equipment must be guaranteed, so that the battery and the motor operate well in the process of cooling and heating.
Related recommendations
-
What is the temperature of the cryogenic cooling circulator?
2154The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
View details -
How to use multiple reactors for high and low temperature integrated machine
2673Multiple reactors high and low temperature integrated machine temperature control system will be connected with thermal conductive synthetic oil and power supply before use, and multiple reactor high and low temperature integrated machine temperat...
View details -
Where do you need low temperature chiller and introduction
1848Even though water is one of the most precious and scarce resources, it is still used as a coolant in many laboratories. Unfortunately, most of the water used as a coolant is not recycled, resulting in higher and higher laboratory costs and wasted ...
View details -
Temperature control system for controlling integrated circuit chip test temperature
2012Advances in semiconductor technology have led to the development of next-generation electronic devices such as integrated circuits, which have more and more active components, higher circuit complexity, smaller area, and tighter wiring. These attr...
View details
LNEYA Thermo Refrigeration Co.,Ltd