Importance of refrigerants in new energy vehicle battery test systems
If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of the expansion valve is often due to lack of cooling. Or the expansion valve flow is not enough, too little refrigerant expansion will not use all the evaporator area, only the low temperature is formed locally in the evaporator, and some areas are rapidly expanded due to the small amount of refrigerant, causing the local temperature to be too low, and the evaporator appears. Frosting.
After local frosting, due to the formation of a thermal insulation layer on the surface of the evaporator, the heat exchange amount in the area is low, the expansion of the refrigerant is transferred to other areas, and the entire evaporator is frosted or frozen, and the entire evaporator is insulated. The layer, then the expansion spreads to the compressor return pipe causing the compressor to return to the air. Since the amount of refrigerant is too small, the evaporation pressure of the evaporator is low, resulting in low evaporation temperature, which will gradually lead to condensation of the evaporator to form a heat insulation layer and transfer the expansion point to the compressor return air to cause the compressor to return to the air. All of the above points will show the evaporator frosting before the compressor of the new energy vehicle battery test system returns to air.
If the new energy vehicle battery test system has a heat bypass valve, then just adjust the hot gas bypass valve. The specific method: open the rear end cover of the hot gas bypass valve, and then use the 8th hex wrench to turn the adjustment inside the clockwise Nut, the adjustment process should not be too fast, generally pause for about half a circle, let the system run for a period of time to see the frost condition and then decide whether to continue to adjust. After the operation is stable, the compressor frosting phenomenon disappears and the end cap is tightened. For models below 15 cubic meters, since there is no hot gas bypass valve, if the frosting phenomenon is serious, the take-off pressure of the pressure switch of the condensing fan can be appropriately adjusted.
Specific method: first find the pressure switch, remove the adjustment nut of the pressure switch to fix the small piece, and then use a Phillips screwdriver to rotate clockwise, the whole adjustment also needs to be carried out slowly, adjust a half circle to see the situation and then decide whether it needs adjustment.
Therefore, the refrigerant in the new energy vehicle battery test system is very important. Secondly, the choice of refrigerant is also very important. The mixed refrigerants of professional manufacturers of production equipment have certain advantages in performance, so it is recommended that users choose according to their own needs.
Related recommendations
-
Detailed introduction of the motor control cooling system Chiller
2920With the continuous development of new energy vehicles, the motor control cooling system Chiller is also under continuous development. The new energy vehicle motor test special chiller can adaptively adjust the cooling capacity of the chiller acco...
View details -
Design and Test Technology of High Temperature Environmental Chamber Sales
29231. Temperature selection (1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products;...
View details -
Advantages of laboratory low-temperature circulators
1722The laboratory low-temperature circulator can simultaneously provide constant temperature and current refrigeration, heating, and temperature control equipment. The laboratory low-temperature circulator has a reasonable structure, simple operati...
View details -
Cooling and heating temperature control equipment for liquid distribution system
1774The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution syste...
View details
LNEYA Thermo Refrigeration Co.,Ltd