What are the causes of the blockage of the cooler?
The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃.
The cycle is closed, there is no oil mist at high temperature and no water vapor at low temperature; Wide working temperature range of heat transfer oil; The entire circulation system without the use of the mechanical and electric valve.
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of the air compressor failure at high temperature is the blockage of the cooler.
Dust is the most common cause of air compressor cooler blockage. It usually happens when there is no dust cleaning for air compressor cooler for a long time. On the other hand is the dusty environment around the air compressor.
If the place of air compressor station is harsh, and it is not well protected, blockage also occurs. For example, things as the broken thread of textile industry, sawdust of furniture factory, iron filings of steel works float in the air and stick to the cooler will lead to blockage.
Some users bought bad-quality air compressor lubricants out of their bargin-loving heart. Or if the air compressor runs in a high temperature for a long time, the inside of the cooler will form carbon and cause blockage. Reducing the amount of lubricating oil flowing through the radiator, results in poor heat dissipation.
There are three main reasons for the blockage of air compressor cooler, and we’d like to inform you to prevent the clogging of the cooler, ensure the normal operation of the cooler and improve the production efficiency. At the same time, it also requires users to clean the coolers daily, do the maintenance work in time, and find professional after-sales staff to deal with the problem.
Related recommendations
-
How do isolated heating refrigeration circulators deal with inefficiencies?
1999Heat dissipation is a common problem that causes inefficiencies in isolated heating refrigeration circulators, and it is also a problem that can easily occur. Many isolated heating and refrigeration circulators will have similar problems, so how t...
View details -
High and low temperature device related instrument maintenance instructions
2031The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
View details -
Heat sink temperature application note
2048As we all know, the semiconductor industry has certain characteristics, small size, high reliability, wide working range, and has a wide range of applications in the civilian, industrial and other fields of semiconductors, but with the increasing ...
View details -
What is the reason why the industrial chiller system cannot be cooled
2441Let the LNEYA technical engineer explainthe reason for everyone: The first one: The chiller system fails tolower the temperature during the first use, or there is a problem with theinstallation of the industrial water chiller, cooling tower, ...
View details
LNEYA Thermo Refrigeration Co.,Ltd